Field Service Ver. 1.0 May 2006
14.3.70
C061: Hold job error/No Duplex unit
14.3.71
C062: Hold job error/No Tray 3
14.3.72
C063: Hold job error/No Tray 4
14.3.73
C064: Hold job error/No Memory
14.3.74
C065: Hold job error/No Tray5
Controller Board (PWB-P)
Step
Turn OFF the Power Switch of the printer
1
and turn it ON again (Restart of the printer.)
Return to the same state as the device
2
configuration when job was held.
Check the options that are mounted on the
3
printer for proper connection and correct as
necessary.
Check the PWB-M connector for proper
4
connection and correct as necessary.
Delete the job hold in [PROOF/PRINT
5
MENU].
14.3.75
FFFF: Interface Communication error
Print Control Board (PWB-P)
Step
Turn OFF the Power Switch of the printer
1
and turn it ON again (Restart of the printer.)
Check the PWB-P connector for proper
2
connection and correct as necessary
Check the PWB-M connector for proper
3
connection and correct as necessary.
4
Change PWB-M.
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
14. Service call message
Mechanical Control Board (PWB-M)
WIRING DIAGRAM
Control Signal
—
—
—
—
—
Mechanical Control Board (PWB-M)
WIRING DIAGRAM
Control Signal
—
—
—
—
Location (Electri-
cal Component)
—
—
—
—
—
Location (Electri-
cal Component)
—
—
—
—
209