Procedure 10-7 Problem: Unable to receive alarms on the 5620 SAM,

or alarm performance is degraded

By default, the system begins purging alarms when the outstanding alarm count reaches
50 000, unless historical alarm record logging and purging alarm policies are configured
to keep the outstanding alarm count below that level.
1
2
3
4
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
iv
Review the information, which includes:
the auxiliary server IP address
the auxiliary server host name
the auxiliary server port number
the auxiliary server type (Reserved or Preferred)
the auxiliary server status (Unknown, Down, Up, or Unused)
v
If the auxiliary server status is Down, perform Procedure
server.
vi
If the auxiliary server status is Unknown, perform Procedure
the connectivity between the managed network and the main and auxiliary
servers.
Close the System Information form.
Caution — Exceeding the alarm limit configured in the nms-server.xml
file may cause system performance problems.
Check the status bar of the 5620 SAM client GUI status bar for indications that the
maximum number of alarms for the system is reached.
If required, clear outstanding alarms or delete them to the alarm history record
log, as described in the 5620 SAM User Guide.
If the 5620 SAM system includes one or more auxiliary servers, perform
Procedure
10-6
to ensure that system performance is not degraded because of
auxiliary-server unavailability.
Contact your Alcatel-Lucent support representative for more information.