Enhanced Motor Learned Data; Trip Counter; Starter Failure; Current Demand/Kw Demand/Kvar Demand/Kva Demand/Analog Outputs - GE 369 Communications Manual

Motor management relay
Hide thumbs Also See for 369:
Table of Contents

Advertisement

MEMORY MAP
CG72
Table CG–10: MEMORY MAP (Sheet 27 of 57)
ADDR
DESCRIPTION
(hex)
1C24
Reverse Power Alarm Delay
1C25
Reverse Power Alarm Events
1C26
Reverse Power Trip
1C27
Assign Trip Relays
1C28
Reverse Power Trip Level
1C29
Reverse Power Trip Delay
...
Reserved
1C70
Number of Starts to Average
1C71
Access Learned Data Record Number
1C80
Trip Counter Alarm
1C81
Assign Alarm Relays
1C82
Alarm Pickup Level
1C83
Trip Counter Alarm Events
...
Reserved
1C90
Starter Failure Alarm
1C91
Starter Type
1C92
Assign Alarm Relays
1C93
Starter Failure Delay
1C94
Starter Failure Alarm Events
...
Reserved
1CD0
Current Demand Period
1CD1
Current Demand Alarm
1CD2
Assign Alarm Relays
1CD3
Current Demand Alarm Limit
1CD5
Current Demand Alarm Events
...
Reserved
1CE0
kW Demand Period
1CE1
kW Demand Alarm
1CE2
Assign Alarm Relays
1CE3
kW Demand Alarm Limit
1CE4
kW Demand Alarm Events
...
Reserved
1CF0
kvar Demand Period
1CF1
kvar Demand Alarm
1CF2
Assign Alarm Relays
1CF3
kvar Demand Alarm Limit
1CF4
kvar Demand Alarm Events
...
Reserved
1D00
kVA Demand Period
1D01
kVA Demand Alarm
1D02
Assign Alarm Relays
1D03
kVA Demand Alarm Limit
1D04
kVA Demand Alarm Events
...
Reserved
1D06
Assign Service Relay
...
Reserved
1D40
Enable Analog Output 1
1D41
Assign Analog Output 1 Output Range
1D42
Assign Analog Output 1 Parameter
1D43
Analog Output 1 Minimum
MIN.
MAX.
STEP
VALUE
5
300
1
0
1
1
0
2
1
0
7
1
1
25000
1
5
300
1

ENHANCED MOTOR LEARNED DATA

1
5
1
0
65535
1

TRIP COUNTER

0
2
1
0
7
1
0
50000
1
0
1
1

STARTER FAILURE

0
2
1
0
1
1
0
7
1
10
1000
10
0
1
1
CURRENT DEMAND
5
90
1
0
2
1
0
7
1
0
65000
1
0
1
1
KW DEMAND
5
90
1
0
2
1
0
7
1
1
50000
1
0
1
1
KVAR DEMAND
5
90
1
0
2
1
0
7
1
1
50000
1
0
1
1
KVA DEMAND
5
90
1
0
2
1
0
7
1
1
50000
1
0
1
1
SELF-TEST RELAY
0
7
1
ANALOG OUTPUTS
0
1
1
0
2
1
0
35
1
TBD
TBD
1
369 MOTOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
CGCOMMUNICATIONS GUIDE
UNITS
FORMAT
FACTORY
CODE
DEFAULT
s
F2
1
-
F103
0
-
F115
0
-
F111
1
kW
F1
1
s
F2
1
-
F1
5
-
F1
0
-
F115
0
-
F113
1
-
F1
25
-
F103
0
-
F115
0
-
F125
0
-
F113
1
ms
F1
100
-
F103
0
min
F1
15
-
F115
0
-
F113
1
A
F1
100
-
F103
0
min
F1
15
-
F115
0
-
F113
1
kW
F1
100
-
F103
0
min
F1
15
-
F115
0
-
F113
1
kvar
F1
100
-
F103
0
min
F1
15
-
F115
0
-
F113
1
kVA
F1
100
-
F103
0
-
F113
0
-
F103
0
-
F26
0
-
F127
0
-
F1
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents