Undervoltage; Overvoltage; Phase Reversal; Overfrequency / Underfrequency / Lead Power Factor - GE 369 Communications Manual

Motor management relay
Hide thumbs Also See for 369:
Table of Contents

Advertisement

MEMORY MAP
CG70
Table CG–10: MEMORY MAP (Sheet 25 of 57)
ADDR
DESCRIPTION
(hex)
1B60
Undervoltage Active If Motor Stopped
1B61
Undervoltage Alarm
1B62
Assign Alarm Relays
1B63
Undervoltage Alarm Pickup
1B64
Starting Undervoltage Alarm Pickup
1B65
Undervoltage Alarm Delay
1B66
Undervoltage Alarm Events
1B67
Undervoltage Trip
1B68
Undervoltage Trip Relays
1B69
Undervoltage Trip Pickup
1B6A
Starting Undervoltage Trip Pickup
1B6B
Undervoltage Trip Delay
...
Reserved
1B80
Overvoltage Alarm
1B81
Overvoltage Alarm Relays
1B82
Overvoltage Alarm Pickup
1B83
Overvoltage Alarm Delay
1B84
Overvoltage Alarm Events
1B85
Overvoltage Trip
1B86
Overvoltage Trip Relays
1B87
Overvoltage Trip Pickup
1B88
Overvoltage Trip Delay
...
Reserved
1BA0
Phase Reversal Trip
1BA1
Assign Trip Relays
...
Reserved
1BB0
Block Overfrequency on Start
1BB1
Overfrequency Alarm
1BB2
Assign Alarm Relays
1BB3
Overfrequency Alarm Level
1BB4
Overfrequency Alarm Delay
1BB5
Overfrequency Alarm Events
1BB6
Overfrequency Trip
1BB7
Assign Trip Relays
1BB8
Overfrequency Trip Level
1BB9
Overfrequency Trip Delay
...
Reserved
1BC0
Block Underfrequency on Start
1BC1
Underfrequency Alarm
1BC2
Assign Alarm Relays
1BC3
Underfrequency Alarm Level
1BC4
Underfrequency Alarm Delay
1BC5
Underfrequency Alarm Events
1BC6
Underfrequency Trip
1BC7
Assign Trip Relays
1BC8
Underfrequency Trip Level
1BC9
Underfrequency Trip Delay
...
Reserved
1BD0
Block Lead Power Factor From Start
1BD1
Lead Power Factor Alarm
1BD2
Assign Lead Power Factor Alarm Relays
1BD3
Lead Power Factor Alarm Level
1BD4
Lead Power Factor Alarm Delay
CGCOMMUNICATIONS GUIDE
MIN.
MAX.
STEP
VALUE

UNDERVOLTAGE

0
1
1
0
2
1
0
7
1
50
99
1
50
99
1
0
2550
1
0
1
1
0
2
1
0
7
1
50
99
1
50
99
1
0
2550
1

OVERVOLTAGE

0
2
1
0
7
1
101
125
1
0
2550
1
0
1
1
0
1
1
0
7
1
101
125
1
0
2550
1

PHASE REVERSAL

0
2
1
0
7
1
-
-
-
OVERFREQUENCY
0
5000
1
0
2
1
0
7
1
2000
7000
1
0
2550
1
0
1
1
0
1
1
0
7
1
2000
7000
1
0
2550
1
-
-
-
UNDERFREQUENCY
0
5000
1
0
2
1
0
7
1
2000
7000
1
0
2550
1
0
1
1
0
2
1
0
7
1
2000
7000
1
0
2550
1
LEAD POWER FACTOR
0
5000
1
0
2
1
0
7
1
5
99
1
1
2550
1
369 MOTOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
UNITS
FORMAT
FACTORY
CODE
DEFAULT
-
F103
0
-
F115
0
-
F113
1
× Rated
F3
85
× Rated
F3
85
0.1s
F2
30
-
F103
0
-
F115
0
-
F111
1
× Rated
F3
80
× Rated
F3
80
0.1s
F2
10
-
F115
0
-
F113
1
x Rated
F3
105
s
F2
10
-
F103
0
-
F103
0
-
F111
1
x Rated
F3
110
s
F2
10
-
F115
0
-
F111
1
-
-
-
s
F1
1
-
F115
0
-
F113
1
Hz
F3
6050
s
F2
10
-
F103
0
-
F103
0
-
F111
1
Hz
F3
6050
s
F2
10
-
-
-
s
F1
1
-
F115
0
-
F113
1
Hz
F3
5950
s
F2
10
-
F103
0
-
F115
0
-
F111
1
Hz
F3
5950
s
F2
10
s
F1
1
-
F115
0
-
F113
1
-
F3
30
s
F2
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents