DEVICENET PROTOCOL
ATTRIBUTE
0Fh
LEARNED DATA
10h
MOTOR
STATISTICS
11h
CAUSE OF LAST
TRIP
12h
LAST PRE-TRIP
DATE AND TIME.
13h
LAST PRE-TRIP
CURRENTS
14h
LAST PRE-TRIP
MOTOR LOAD
15h
PRE-TRIP STATOR
RTD TEMP.
16h
LAST PRE-TRIP
LINE VOLTAGES
17h
LAST PRE-TRIP
PHASE VOLTAGES
18h
LAST PRE-TRIP
FREQ.
19h
LAST PRE-TRIP
POWER
1Ah
TRIP DIAG.
1Bh
ALARM DIAG.
1Ch
START BLOCK
STATUS
CG32
DATA FORMATS FOR CLASS CODE B0H, INSTANCE 1 (Sheet 3 of 6)
BYTES
DESCRIPTION
1,2 (low, high)
Learned acceleration time
3,4 (low, high)
Learned starting current
5,6 (low, high)
Learned starting capacity
Learned running cool time
7,8 (low, high)
constant
Learned stopped cool time
9,10 (low, high)
constant
11,12 (low, high)
Last starting capacity
Learned unbalance k-
13,14 (low, high)
factor
1,2 (low, high)
Number of starts
3,4 (low, high)
Number of restarts
5,6 (low, high)
Digital counter
7,8 (low, high)
Motor running hours
1,2 (low, high)
Cause of last trip
1 to 4(low, high)
Last trip date
5 to 8(low, high)
Last trip time
1,2 (low, high)
Last pre-trip Ia
3,4 (low, high)
Last pre-trip Ib
5,6 (low, high)
Last pre-trip Ic
7,8 (low, high)
Last pre-trip Ig
1,2 (low, high)
Last pre-trip motor load
3,4 (low, high)
Last pre-trip unbalance
Local pre-trip hottest
1,2 (low, high)
stator RTD
Local pre-trip hottest
3,4 (low, high)
stator RTD temperature
1,2 (low, high)
Last pre-trip Vab
3,4 (low, high)
Last pre-trip Vbc
5,6 (low, high)
Last pre-trip Vca
1,2 (low, high)
Last pre-trip Van
3,4 (low, high)
Last pre-trip Vbn
5,6 (low, high)
Last pre-trip Vcn
1,2 (low, high)
Last pre-trip frequency
1,2 (low, high)
Last pre-trip kilowatts
3,4 (low, high)
Last pre-trip kvar
5,6 (low, high)
Last pre-trip KVA
7,8 (low, high)
Last pre-trip power factor
6 bytes
Trip diagnostic data
8 bytes
Alarm diagnostic data
1,2 (low, high)
Overload lockout timer
3,4 (low, high)
Starts timer [1]
5,6 (low, high)
Starts timer [2]
7,8 (low, high)
Starts timer [3]
9,10 (low, high)
Starts timer [4]
11,12 (low, high)
Starts timer [5]
13,14 (low, high)
Time between starts timer
15,16 (low, high)
Restart block timer
17,16 (low, high)
Start inhibit timer
CGCOMMUNICATIONS GUIDE
LENGTH
FORMAT
16 bits
F2
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
F134
32 bits
F18
32 bits
F19
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
F2
16 bits
F3
16 bits
UINT
16 bits
UINT
16 bits
F4
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
F3
16 bits
F4
16 bits
F4
16 bits
UINT
16 bits
F21
48 bits
F176
64 bits
F177
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
16 bits
UINT
369 MOTOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
VALUE/UNIT
x 0.1 seconds
A
%
minutes
minutes
%
--
--
--
--
hours
--
--
--
A
A
A
0.1 × A
× 0.01 FLA
%
---
°C
volts
volts
volts
volts
volts
volts
× 0.01 Hz
kW
kvar
kVA
× 0.01 PF
minutes
minutes
minutes
minutes
minutes
minutes
minutes
seconds
minutes