Rrtd 2 – Rtd #5; Rrtd 2 – Rtd #6; Rrtd 2 – Rtd #7; Rrtd 2 – Rtd #8 - GE 369 Communications Manual

Motor management relay
Hide thumbs Also See for 369:
Table of Contents

Advertisement

MEMORY MAP
CG80
Table CG–10: MEMORY MAP (Sheet 35 of 57)
ADDR
DESCRIPTION
(hex)
2280
RRTD 2 - RTD #5 Application
2281
RRTD 2 - RTD #5 High Alarm
2282
RRTD 2 - RTD #5 High Alarm Relays
2283
RRTD 2 - RTD #5 High Alarm Level
2284
RRTD 2 - RTD #5 Alarm
2285
RRTD 2 - RTD #5 Alarm Relays
2286
RRTD 2 - RTD #5 Alarm Level
2287
Record RRTD 2 - RTD #5 Alarms as Events 0
2288
RRTD 2 - RTD #5 Trip
2289
Enable RRTD 2 - RTD #5 Trip Voting
228A
RRTD 2 - RTD #5 Trip Relays
228B
RRTD 2 - RTD #5 Trip Level
228C
RRTD 2 - RTD #5 RTD Type
2290
First Character of RRTD 2 - RTD #5 Name
2293
8th Character of RRTD 2 - RTD #5 Name
...
Reserved
22A0
RRTD 2 - RTD #6 Application
22A1
RRTD 2 - RTD #6 High Alarm
22A2
RRTD 2 - RTD #6 High Alarm Relays
22A3
RRTD 2 - RTD #6 High Alarm Level
22A4
RRTD 2 - RTD #6 Alarm
22A5
RRTD 2 - RTD #6 Alarm Relays
22A6
RRTD 2 - RTD #6 Alarm Level
22A7
Record RRTD 2 - RTD #6 Alarms as Events 0
22A8
RRTD 2 - RTD #6 Trip
22A9
Enable RRTD 2 - RTD #6 Trip Voting
22AA
RRTD 2 - RTD #6 Trip Relays
22AB
RRTD 2 - RTD #6 Trip Level
22AC
RRTD 2 - RTD #6 RTD Type
22B0
First Character of RRTD 2 - RTD #6 Name
22B3
8th Character of RRTD 2 - RTD #6 Name
...
Reserved
22C0
RRTD 2 - RTD #7 Application
22C1
RRTD 2 - RTD #7 High Alarm
22C2
RRTD 2 - RTD #7 High Alarm Relays
22C3
RRTD 2 - RTD #7 High Alarm Level
22C4
RRTD 2 - RTD #7 Alarm
22C5
RRTD 2 - RTD #7 Alarm Relays
22C6
RRTD 2 - RTD #7 Alarm Level
22C7
Record RRTD 2 - RTD #7 Alarms as Events 0
22C8
RRTD 2 - RTD #7 Trip
22C9
Enable RRTD 2 - RTD #7 Trip Voting
22CA
RRTD 2 - RTD #7 Trip Relays
22CB
RRTD 2 - RTD #7 Trip Level
22CC
RRTD 2 - RTD #7 RTD Type
22D0
First Character of RRTD 2 - RTD #7 Name
22D3
8th Character of RRTD 2 - RTD #7 Name
...
Reserved
22E0
RRTD 2 - RTD #8 Application
22E1
RRTD 2 - RTD #8 High Alarm
22E2
RRTD 2 - RTD #8 High Alarm Relays
22E3
RRTD 2 - RTD #8 High Alarm Level
CGCOMMUNICATIONS GUIDE
MIN.
MAX.
STEP
VALUE
RRTD 2 – RTD #5
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
0
2
1
-
0
7
1
-
1
200
1
°C
1
1
-
0
2
1
-
0
13
1
-
0
7
1
-
1
200
1
°C
0
3
1
-
32
127
1
-
32
127
1
-
RRTD 2 – RTD #6
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
0
2
1
-
0
7
1
-
1
200
1
°C
1
1
-
0
2
1
-
0
13
1
-
0
7
1
-
1
200
1
°C
0
3
1
-
32
127
1
-
32
127
1
-
RRTD 2 – RTD #7
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
0
2
1
-
0
7
1
-
1
200
1
°C
1
1
-
0
2
1
-
0
13
1
-
0
7
1
-
1
200
1
°C
0
3
1
-
32
127
1
-
32
127
1
-
RRTD 2 – RTD #8
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
369 MOTOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
UNITS
FORMAT
FACTORY
CODE
DEFAULT
F121
0
F115
0
F113
2
F1
130
F115
0
F113
1
F1
130
F103
0
F115
0
F122
1
F111
1
F1
130
F120
0
F1
'R'
F1
" "
F121
0
F115
0
F113
1
F1
130
F115
0
F113
1
F1
130
F103
0
F115
0
F122
1
F111
1
F1
130
F120
0
F1
'R'
F1
" "
F121
0
F115
0
F113
2
F1
130
F115
0
F113
1
F1
130
F103
0
F115
0
F122
1
F111
1
F1
130
F120
0
F1
'R'
F1
' '
F121
0
F115
0
F113
2
F1
130

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents