Speed 2 Acceleration; Test Output Relays / Test Analog Outputs; Remote Rtd Slave Addresses; Rrtd 1- Rtd #1 - GE 369 Communications Manual

Motor management relay
Hide thumbs Also See for 369:
Table of Contents

Advertisement

MEMORY MAP
CG74
Table CG–10: MEMORY MAP (Sheet 29 of 57)
ADDR
DESCRIPTION
(hex)
1DF8
Speed 2 Undercurrent Trip Level
1DF9
Speed 2 Undercurrent Trip Delay
...
Reserved
1E00
Speed 2 Acceleration Timer from Start
Speed 2 Acceleration Timer from Speed 1
1E01
to 2
1E02
Speed 2 Speed Switch Time Delay
1E20
Start/Stop Data Log
1E21
Log Interval
1E22
Recording Type
1E23
Data Log Memory Access Block Number
1E24
Channel 1 Log Assignment
1E25
Channel 2 Log Assignment
1E26
Channel 3 Log Assignment
1E27
Channel 4 Log Assignment
1E28
Channel 5 Log Assignment
1E29
Channel 6 Log Assignment
1E2A
Channel 7 Log Assignment
1E2B
Channel 8 Log Assignment
1E2C
Channel 9 Log Assignment
1E2D
Channel 10 Log Assignment
1E2E
Channel 11 Log Assignment
1E2F
Channel 12 Log Assignment
1E30
Channel 13 Log Assignment
1E31
Channel 14 Log Assignment
1E32
Channel 15 Log Assignment
1E33
Channel 16 Log Assignment
...
Reserved
1F80
Force Trip Relay
1F81
Force Trip Relay Duration
1F82
Force AUX1 Relay
1F83
Force AUX1 Relay Duration
1F84
Force AUX2 Relay
1F85
Force AUX2 Relay Duration
1F86
Force Alarm Relay
1F87
Force Alarm Relay Range
...
Reserved
1F90
Force Analog Outputs
1F91
Analog Output 1 Forced Value
1F92
Analog Output 2 Forced Value
1F93
Analog Output 3 Forced Value
1F94
Analog Output 4 Forced Value
...
Reserved
1FF0
RRTD1 - Slave Address
1FF1
RRTD2 - Slave Address
1FF2
RRTD3 - Slave Address
1FF3
RRTD4 - Slave Address
...
Reserved
2000
RRTD 1 - RTD #1 Application
2001
RRTD 1 - RTD #1 High Alarm
2002
RRTD 1 - RTD #1 High Alarm Relays
2003
RRTD 1 - RTD #1 High Alarm Level
MIN.
MAX.
STEP
VALUE
10
99
1
1
255
1

SPEED 2 ACCELERATION

10
2500
10
20
2500
1
5
1000
5
DATA LOGGER
0
2
1
0
3600
1
0
1
1
0
255
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
0
102
1
TEST OUTPUT RELAYS
0
2
1
1
300
1
0
2
1
1
300
1
0
2
1
1
300
1
0
2
1
1
300
1
TEST ANALOG OUTPUTS
0
1
1
0
100
1
0
100
1
0
100
1
0
100
1

REMOTE RTD SLAVE ADDRESSES

0
254
1
0
254
1
0
254
1
0
254
1
RRTD 1 – RTD #1
0
4
1
0
2
1
0
7
1
1
200
1
369 MOTOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
CGCOMMUNICATIONS GUIDE
UNITS
FORMAT
FACTORY
CODE
DEFAULT
0.01 × FLA F3
70
s
F1
1
s
F2
100
s
F2
200
100 ms
F2
20
0 (=Select
-
F187
Command)
-
F1
3600
0 (=Run To
-
F188
Fill)
-
F1
0, 1 (=null)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F189
0 (=None)
-
F150
0
s
F1
0
-
F150
0
s
F1
0
-
F150
0
s
F1
0
-
F150
0
s
F1
0
-
F126
0
% range
F1
0
% range
F1
0
% range
F1
0
% range
F1
0
-
F1
0
-
F1
0
-
F1
0
-
F1
0
-
F121
0
-
F115
0
-
F113
2
°C
F1
130

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents