Table CG–10: MEMORY MAP (Sheet 34 of 57)
ADDR
DESCRIPTION
(hex)
220C
RRTD 2 - RTD #1 RTD Type
2210
First Character of RRTD 2 - RTD #1 Name
2213
8th Character of RRTD 2 - RTD #1 Name
...
Reserved
2220
RRTD 2 - RTD #2 Application
2221
RRTD 2 - RTD #2 High Alarm
2222
RRTD 2 - RTD #2 High Alarm Relays
2223
RRTD 2 - RTD #2 High Alarm Level
2224
RRTD 2 - RTD #2 Alarm
2225
RRTD 2 - RTD #2 Alarm Relays
2226
RRTD 2 - RTD #2 Alarm Level
2227
Record RRTD 2 - RTD #2 Alarms as Events 0
2228
RRTD 2 - RTD #2 Trip
2229
Enable A Remote RTD #2 Trip Voting
222A
RRTD 2 - RTD #2 Trip Relays
222B
RRTD 2 - RTD #2 Trip Level
222C
RRTD 2 - RTD #2 RTD Type
2230
First Character of RRTD 2 - RTD #2 Name
2233
8th Character of RRTD 2 - RTD #2 Name
...
Reserved
2240
RRTD 2 - RTD #3 Application
2241
RRTD 2 - RTD #3 High Alarm
2242
RRTD 2 - RTD #3 High Alarm Relays
2243
RRTD 2 - RTD #3 High Alarm Level
2244
RRTD 2 - RTD #3 Alarm
2245
RRTD 2 - RTD #3 Alarm Relays
2246
RRTD 2 - RTD #3 Alarm Level
2247
Record RRTD 2 - RTD #3 Alarms as Events 0
2248
RRTD 2 - RTD #3 Trip
2249
Enable RRTD 2 - RTD #3 Trip Voting
224A
RRTD 2 - RTD #3 Trip Relays
224B
RRTD 2 - RTD #3 Trip Level
224C
RRTD 2 - RTD #3 RTD Type
2250
First Character of RRTD 2 - RTD # Name
2253
8th Character of RRTD 2 - RTD #3 Name
...
Reserved
2260
RRTD 2 - RTD #4 Application
2261
RRTD 2 - RTD #4 High Alarm
2262
RRTD 2 - RTD #4 High Alarm Relays
2263
RRTD 2 - RTD #4 High Alarm Level
2264
RRTD 2 - RTD #4 Alarm
2265
RRTD 2 - RTD #4 Alarm Relays
2266
RRTD 2 - RTD #4 Alarm Level
2267
Record RRTD 2 - RTD #4 Alarms as Events 0
2268
RRTD 2 - RTD #4 Trip
2069
Enable RRTD 2 - RTD #4 Trip Voting
226A
RRTD 2 - RTD #4 Trip Relays
226B
RRTD 2 - RTD #4 Trip Level
226C
RRTD 2 - RTD #4 RTD Type
2270
First Character of RRTD 2 - RTD #4 Name
2273
8th Character of RRTD 2 - RTD #4 Name
...
Reserved
MIN.
MAX.
STEP
VALUE
0
3
1
-
32
127
1
-
32
127
1
-
RRTD 2 – RTD #2
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
0
2
1
-
0
7
1
-
1
200
1
°C
1
1
-
0
2
1
-
0
13
1
-
0
7
1
-
1
200
1
°C
0
3
1
-
32
127
1
-
32
127
1
-
RRTD 2 – RTD #3
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
0
2
1
-
0
7
1
-
1
200
1
°C
1
1
-
0
2
1
-
0
13
1
-
0
7
1
-
1
200
1
°C
0
3
1
-
32
127
1
-
32
127
1
-
RRTD 2 – RTD #4
0
4
1
-
0
2
1
-
0
7
1
-
1
200
1
°C
0
2
1
-
0
7
1
-
1
200
1
°C
1
1
-
0
2
1
-
0
13
1
-
0
7
1
-
1
200
1
°C
0
3
1
-
32
127
1
-
32
127
1
-
MEMORY MAP
UNITS
FORMAT
FACTORY
CODE
DEFAULT
F120
0
F1
'R'
F1
" "
F121
0
F115
0
F113
2
F1
130
F115
0
F113
1
F1
130
F103
0
F115
0
F122
1
F111
1
F1
130
F120
0
F1
'R'
F1
" "
F121
0
F115
0
F113
2
F1
130
F115
0
F113
1
F1
130
F103
0
F115
0
F122
1
F111
1
F1
130
F120
0
F1
'R'
F1
" "
F121
0
F115
0
F113
2
F1
130
F115
0
F113
1
F1
130
F103
0
F115
0
F122
1
F111
1
F1
130
F120
0
F1
'R'
F1
" "
CG79