G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANEL
B
PROGRAMMING THE DOOR PANEL
Programming fields:
The module is pre-programmed with factory settings except for the activation codes, which are left empty for security
reasons. For system operation tailored to the needs of the user, check the values set in all of the fields. The fields do not
need to be programmed in numerical order.
Enter programming mode:
Step 1: Press the bell button (N3301/GB2), followed by the administrator code, and confirm with the bell button on
the module (N3301/GB2).
Step 2: Then press the field number:
Field '01': Sets the administrator code.
Steps: Field + bell (N3301/GB2) + administrator code + bell (N3301/GB2).
(Step 1)
(Step 2)
...
(Step 3)
0
(Step 4)
(Step 5)
03
Bell (N3301/GB2) + administrator code + bell (N3301/GB2).
01
Press '01' to select field '01'.
01
Press the bell button (N3301/GB2) to finish programming the field.
Define the new administrator code using the numeric buttons from 0 to 9. The maximum
9
length of the administrator code is 12 digits.
The factory setting is 1234
Press the bell button (N3301/GB2) to confirm the selection of the
Then press the number of the next field to configure or press the C button (cancel)
C
or
to exit programming mode.
1
2
3
4
...
0
9
19
field.