Display mode
In normal operation, up to 4 different operating
variables can be indicated continuously: 1.1 and 1.2
and 1.3 and 2, and in line 4 the present operating
status or alarms and warnings that have arisen.
VAR 1.1 VAR 1.2 VAR 1.3
VAR 2
STATUS
Display mode - selection of read-outstate
There are three options in connection with the
choice of read-out state in the Display mode - I, II
and III. The choice of read-out state determines the
number of operating variables read out.
Read-out state:
I:
Line 1
Description
for operating
variable in line 2
The table below gives the units linked to the variables
in the first and second line of the display.
MG.50.R3.02 -
SETUP
1
II:
III:
Data value for
Description for
3 operating
3 operating
variables in line
variables in line
1
1
AKD 5000
O O O O p p p p e e e e r r r r a a a a t t t t i i i i n n n n g g g g v v v v a a a a r r r r i i i i a a a a b b b b l l l l e e e e : : : :
Reference
Reference
Feedback
Frequency
Frequency x scaling
Motor current
Torque
Power
Power
Output energy
Motor voltage
DC-link voltage
Motor thermal load
AKD thermal load
Hours run
Input status, dig. Input
Input status, analogue terminal 53
Input status, analogue terminal 54
Input status, analogue terminal 60
Pulse reference
External reference
Status word
Brake effect/2 min.
Brake effect/sec.
Heat sink temp.
Alarm word
Control word
Warning word 1
Extended status word
Communication option card warning
RPM
RPM x scaling
Operating variables 1.1 and 1.2 and 1.3 in the first
line, and operating variable 2 in the second line are
selected via parameter 009, 010, 011 and 012.
Read-out state I:
This read-out state is standard after starting
up or after initialisation.
FREQUENCY
50.0 Hz
MOTOR IS RUNNING
Line 2 gives the data value of an operating variable with
related unit, and line 1 provides a text which explains
line 2, cf. table. In the example, Frequency has
been selected as variable via parameter 009. During
normal operation another variable can immediately
be read out by using the [+/-] keys.
Read-out state II:
Switching between read-out states I and II is effected
by pressing the [DISPLAY / STATUS] key.
U U U U n n n n i i i i t t t t : : : :
[%]
[unit]
[unit]
[Hz]
[-]
[A]
[%]
[kW]
[HP]
[kWh]
[V]
[V]
[%]
[%]
[Hours]
[Binary code]
[V]
[V]
[mA]
[Hz]
[%]
[Hex]
[kW]
[kW]
[ºC]
[Hex]
[Hex]
[Hex]
[Hex]
[Hex]
-1
[min
]
[ - ]
45