Danfoss AB-QM series Installation Manual
Danfoss AB-QM series Installation Manual

Danfoss AB-QM series Installation Manual

Advertisement

Installation Guide
AB-QM DN 40-100
DN 40/50
Installation / Montering / Einbau / Installation /Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж /
Instalace / 安装 / Vgradnja / Instalación / Montavimas
AME 435 QM
IP 54
Heating Solutions
DN 50
DN 40/50
VI.A7.E4.3T
DN 65-100
DN 50
+
AME 435 QM
+
Code No.: 003Z0695
DN 65-100
SMT/SI
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AB-QM series and is the answer not in the manual?

Questions and answers

willy conway
May 2, 2025

when installing a picv do I need enough straight before and after the valve

1 comments:
Mr. Anderson
May 16, 2025

No, Danfoss LENO valves do not require a specific length of straight pipe before or after the valve. The flow through the valve is symmetrical and not influenced by turbulence from other system components, allowing flexible installation with high measuring accuracy.

This answer is automatically generated

Summary of Contents for Danfoss AB-QM series

  • Page 1 Installation Guide AB-QM DN 40-100 DN 40/50 DN 50 DN 65-100 Installation / Montering / Einbau / Installation /Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж / Instalace / 安装 / Vgradnja / Instalación / Montavimas AME 435 QM IP 54 DN 40/50...
  • Page 2 Installation Guide AB-QM DN 40-100 Shut off / Afspærring / Absperrung / Fermeture / Afsluiten / Avstängning / Sulkuventtiili / Funkcja odcięcia / Aizvēršana / Elzárás / KAPAMA / Отключение /Uzavření / 关闭 / Zapiranje pretoka / Corte / Uždarymas DN 65-100 DN 40, DN 50 Δp max = 16 bar...
  • Page 3 Installation Guide AB-QM DN 40-100 Locking / Låsning / Blockierung / Verrouillage / Vergrendelen / Låsning / Lukitseminen / Blokowanie nastawy / Noslēgšana / Korlátozás / Kilitle / Блокировка / Uzamykání / 锁定 / Blokiranje / Bloqueo / Blokavimas DN 40/50 DN 65-100 Measuring / Måling / Messung / Mesure / Meten / Mätning / Mittaaminen / Wykonywanie pomiarów / Mērīšana / Mérés / Ölçüm / Измерение...
  • Page 4 32300 8,97 142,2 25200 7,00 111,0 34200 9,50 150,6 26600 7,39 117,1 36100 10,03 158,9 100% 28000 7,78 123,3 100% 38000 10,56 167,3 Note: 1 turn = 10% Note: 1 turn = 10% 73693790/VI.A7.E4.3T Produced by Danfoss A/S © 11/2014...
  • Page 5 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж /Instalace / 安装 / Vgradnja / Instalación / Montavimas DN 125/150 DN 200/250 AME 55 QM AME 85 QM Code No.: 003Z0696 Code No.: 003Z0697 VI.C6.C5.8Y | 1 © Danfoss | 2016.02...
  • Page 6 AME 55 QM AME 85 QM PN 16 Δp = 600 kPa* Temp. −10 ... 120 ° max. In case AB-QM is used above 400 kPa differential pressure contact Danfoss design center to assure proper design. VI.C6.C5.8Y 2 | © Danfoss| 2016.02...
  • Page 7 44,86 130.500 36,25 171.000 47,50 137.750 38,26 180.500 50,14 100% 145.000 40,28 190.000 52,78 105% 152.500 42,36 209.500 58,19 110% 160.000 44,44 229.000 63,61 1.008 AB-QM DN 150 Note: 1 turn = 5,0% VI.C6.C5.8Y © Danfoss | 2016.02 | 3...
  • Page 8 Note: 1 turn = 5,0% Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed.

Table of Contents

Save PDF