The Reason field shows the reason for the operational status.
8.
To disable the Short Reach Admin mode for port g1, g2, g3, or g4, from the Short Reach
Admin mod, select Disable.
The Energy Detect Admin Mode is enabled globally, but you can disable it for ports g1–g4
only. With this mode enabled, the port transitions to low power mode when the cable
length is too short.
The Operational Status field shows whether the short reach operational status is active or
inactive.
The Reason field shows the reason for the operational status.
9.
Use the EEE Admin Mode menu to enable or disable this option on the port.
With the EEE mode enabled, the port transitions to low power mode during a link idle
condition. The default value is Disable.
10.
Click the Apply button.
Your settings are saved.
11.
To refresh the page, click the Refresh button.
12.
To clear the configuration, resetting all statistics for the selected interface to default values,
click the Clear button.
The following table describes the nonconfigurable fields.
Table 12. Green Ethernet Local Device Information
Field
Tw_sys_tx (uSec)
Tw_sys_tx Echo (uSec)
Tw_sys_rx (uSec)
Tw_sys_rx Echo (uSec)
View Green Ethernet Information for Remote Devices
To view green Ethernet information for remote devices:
1.
Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2.
Launch a web browser.
3.
In the address field of your web browser, enter the IP address of the switch.
Smart Managed Pro Switches MS510TX and MS510TXPP
Description
The value of Tw_sys that the local system can support.
The remote system's Transmit Tw_sys that was used by the local
system to compute the Tw_sys that is requested from the remote
system.
The value of Tw_sys that the local system requests from the remote
system.
The remote system's Receive Tw_sys that is used by the local system
to compute the Tw_sys that it can support.