7. SPECIAL ADJUSTMENT FUNCTIONS

7.2.4 Gain switching procedure

This operation will be described by way of setting examples.
(1) When you choose switching by control command from the controller
(a) Setting example
Parameter
Symbol
PB06
GD2
Load to motor inertia ratio/load to motor mass ratio
PB07
PG1
Model loop gain
PB08
PG2
Position loop gain
PB09
VG2
Speed loop gain
PB10
VIC
Speed integral compensation
PB19
VRF11
Vibration suppression control 1 - Vibration frequency
PB20
VRF12
Vibration suppression control 1 - Resonance frequency
PB21
VRF13
Vibration suppression control 1 - Vibration frequency damping
PB22
VRF14
Vibration suppression control 1 - Resonance frequency damping
PB52
VRF21
Vibration suppression control 2 - Vibration frequency
PB53
VRF22
Vibration suppression control 2 - Resonance frequency
PB54
VRF23
Vibration suppression control 2 - Vibration frequency damping
PB55
VRF24
Vibration suppression control 2 - Resonance frequency damping
PB29
GD2B
Load to motor inertia ratio/load to motor mass ratio after gain
switching
PB60
PG1B
Model loop gain after gain switching
PB30
PG2B
Position loop gain after gain switching
PB31
VG2B
Speed loop gain after gain switching
PB32
VICB
Speed integral compensation after gain switching
PB26
CDP
Gain switching function
PB28
CDT
Gain switching time constant
PB33
VRF11B Vibration suppression control 1 - Vibration frequency after gain
switching
PB34
VRF12B Vibration suppression control 1 - Resonance frequency after gain
switching
PB35
VRF13B Vibration suppression control 1 - Vibration frequency damping after
gain switching
PB36
VRF14B Vibration suppression control 1 - Resonance frequency damping
after gain switching
PB56
VRF21B Vibration suppression control 2 - Vibration frequency after gain
switching
PB57
VRF22B Vibration suppression control 2 - Resonance frequency after gain
switching
PB58
VRF23B Vibration suppression control 2 - Vibration frequency damping after
gain switching
PB59
VRF24B Vibration suppression control 2 - Resonance frequency damping
after gain switching
Name
7 - 20
Setting value
4.00
100
120
3000
20
50
50
0.20
0.20
20
20
0.10
0.10
10.00
50
84
4000
50
0001
(Switch by control command
from the controller.)
100
60
60
0.15
0.15
30
30
0.05
0.05
Unit
[Multiplier]
[rad/s]
[rad/s]
[rad/s]
[ms]
[Hz]
[Hz]
[Hz]
[Hz]
[Multiplier]
[rad/s]
[rad/s]
[rad/s]
[ms]
[ms]
[Hz]
[Hz]
[Hz]
[Hz]