14. USING A LINEAR SERVO MOTOR
CAUTION
This chapter does not describe the following items. For details of the items, refer to each section of the
detailed description field.
Connect the servo amplifier power output (U/V/W) to the linear servo motor power
input (U/V/W) directly. Do not let a magnetic contactor, etc. intervene. Otherwise,
it may cause a malfunction.
Servo amplifier
U
V
W
Before wiring, switch operation, etc., eliminate static electricity. Otherwise, it may
cause a malfunction.
Do not modify the equipment.
The cables such as power wires deriving from the primary side cannot stand the
long-term bending action. Avoid the bending action by fixing the cables to the
moving part, etc. Also, use the cable that stands the long-term bending action for
the wiring to the servo amplifier.
Connecting a linear servo motor for different axis to the CNP3A, CNP3B, or
CNP3C connector may cause a malfunction.
Input power supply circuit
Explanation of power supply system
Signal (device) explanations
Alarm occurrence timing chart
Interfaces
SSCNET III cable connection
Grounding
Switch setting and display of the servo
amplifier
Linear servo
Servo amplifier
motor
U
V
M
W
Item
Section 3.1
Section 3.3
Section 3.5
Section 3.7
Section 3.8
Section 3.9
Section 3.11
Section 4.3
14 - 4
Linear servo
U
U
V
V
W
W