Mitsubishi Electric MR-J4W2-0303B6 Instruction Manual page 130

General-purpose ac servo melservo-j4 sscnet /h interface multi-axis ac servo mr-j4w series servo amplifier
Hide thumbs Also See for MR-J4W2-0303B6:
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PB45
CNHF
Setting value
_ 0 _ _
_ 1 _ _
_ 2 _ _
_ 3 _ _
_ 4 _ _
_ 5 _ _
_ 6 _ _
_ 7 _ _
PB46
NH3
Machine resonance suppression filter 3
Set the notch frequency of the machine resonance suppression filter 3.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 3 selection" in [Pr. PB47].
PB47
NHQ3
Notch shape selection 3
Set the shape of the machine resonance suppression filter 3.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PB48
NH4
Machine resonance suppression filter 4
Set the notch frequency of the machine resonance suppression filter 4.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 4 selection" in [Pr. PB49].
Name and function
Table 5.6 Notch depth selection
Depth [dB]
-40.0
-24.1
-18.1
-14.5
-12.0
-10.1
-8.5
-7.2
Explanation
Machine resonance suppression filter 3 selection
0: Disabled
1: Enabled
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
For manufacturer setting
Setting value
Depth [dB]
_ 8 _ _
-6.0
_ 9 _ _
-5.0
_ A _ _
-4.1
_ B _ _
-3.3
_ C _ _
-2.5
_ D _ _
-1.8
_ E _ _
-1.2
_ F _ _
-0.6
5 - 33
Initial
Setting
value
range
[unit]
Refer to Name
and function
column.
4500
10 to
[Hz]
4500
Refer to Name
and function
column.
Initial
value
0h
0h
0h
0h
4500
10 to
[Hz]
4500
Each/
Common
Each
Each
Each
Each