5. PARAMETERS
No.
Symbol
PB06
GD2
Load to motor inertia ratio/load to motor mass ratio
Set a load to motor inertia ratio or load to motor mass ratio. Setting a value
considerably different from the actual load moment of inertia or load mass may cause
an unexpected operation such as an overshoot.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the following table for details. When the parameter
is automatic setting, the value will vary between 0.00 and 100.00.
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB07
PG1
Model loop gain
Set the response gain up to the target position.
Increasing the setting value will also increase the response level to the position
command but will be liable to generate vibration and noise.
For the vibration suppression control tuning mode, the setting range of [Pr. PB07] is
limited. Refer to section 7.1.5 (4) for details.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the following table for details.
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB08
PG2
Position loop gain
Set a gain of the position loop.
Set this parameter to increase the position response to level load disturbance.
Increasing the setting value will also increase the response level to the load
disturbance but will be liable to generate vibration and noise.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the following table for details.
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB09
VG2
Speed loop gain
Set a gain of the speed loop.
Set this parameter when vibration occurs on machines of low rigidity or large
backlash. Increasing the setting value will also increase the response level but will be
liable to generate vibration and noise.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the table of [Pr. PB08] for details.
Name and function
Pr. PA08
Pr. PA08
Pr. PA08
5 - 24
This parameter
Automatic setting
Manual setting
This parameter
Manual setting
Automatic setting
Manual setting
This parameter
Automatic setting
Manual setting
Automatic setting
Initial
Setting
Each/
value
range
Common
[unit]
7.00
0.00 to
Each
300.00
[Multiplier]
15.0
1.0 to
Each
[rad/s]
2000.0
37.0
1.0 to
Each
[rad/s]
2000.0
823
20 to
Each
[rad/s]
65535