18. MR-J4W2-0303B6 SERVO AMPLIFIER
(b) Cable connection procedure
1) Fabrication on cable insulator
Refer to table 18.1 for stripped length of cable insulator. The appropriate stripped length of cables
depends on their type, etc. Set the length considering their fabrication status.
Twist strands lightly and straighten them as follows.
You can also use a ferrule to connect with the connectors. When you use a ferrule, use the
following ferrules and crimp terminal.
2) Inserting wire
When using solid wire, insert the wire to the end. When using stranded wire, insert the wire to the
end with pushing down the release button with a small flat head screwdriver, etc.
The following show a connection example when using stranded wire to the CNP 1 connector.
Insulator
Stripped length 10 mm
Loose and bent strands
Ferrule model (Phoenix Contact)
Wire size
For one
AWG 20
AI0.25-10YE
AWG 18
AI0.34-10TQ
AWG 18
AI0.5-10WH
AWG 16
AI0.75-10GY
Release button
Stranded wire
18 - 20
Core
Twist and straighten
the strands.
For two
Crimping tool
(Phoenix Contact)
CRIMPFOX6