17. APPLICATION OF FUNCTIONS
(b) Operation when using a servo amplifier after change of specifications
For the controllers in which "Not required" is described to controller reset in table 17.3, the mode will
be switched to "J3 compatibility mode" for all axes at the first connection. It takes about 10 s for
completing the connection not depending on the number of axes.
For the controllers in which "Reset required" is described in table 17.3, the operation at the first
connection is shown in table 17.4. The servo amplifier's mode will be "J3 compatibility mode" and the
LED displays will be "rST" for all axes at the first connection to the controller as shown in table 17.4.
At the status, resetting controller once will change the display to "b##" (## means axis No.) for all
axes and all axes will be ready to connect.
(One controller reset enables to all-axis connection.)
(c) Using servo amplifiers before and after change of specifications simultaneously
When using servo amplifiers before change of specifications and after change of specifications
simultaneously, controller reset is necessary for number of connecting axes of servo amplifiers.
Table 17.3 Controller reset required/not required list (after change of specifications)
Controller
Motion controller
Simple motion module
Positioning module
Table 17.4 Controller connection operation after change of specifications
First connection of controller
After controller reset
Model
R_MTCPU
Q17_DSCPU
Q17_DCPU
Q17_HCPU
Q170MCPU
RD77MS_
QD77MS_
LD77MS_
QD75MH_
QD74MH_
LD77MH_
FX3U-20SSC-H
After change of specifications (software version A5 or later)
"rST" is displayed only for the first connection.
Controller
r
S T
r
S T
Axis
Axis
No. 1
No. 2
All axes are connected by one reset.
Controller
b
0 1
b
0 2
Axis
Axis
No. 1
No. 2
17 - 10
Controller reset required/not required
Single-axis
Multi-axis connection
connection
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Reset required
Reset required
Not required
Not required
Reset required
Reset required
r
S T
Axis
No. 3
b
0 3
Axis
No. 3