Mitsubishi Electric MR-J4W2-0303B6 Instruction Manual page 543

General-purpose ac servo melservo-j4 sscnet /h interface multi-axis ac servo mr-j4w series servo amplifier
Hide thumbs Also See for MR-J4W2-0303B6:
Table of Contents

Advertisement

APPENDIX
(4) CN10
Device
Symbol
A-axis shutdown 2
SDI2A+
SDI2A-
B-axis shutdown 2
SDI2B+
SDI2B-
A-axis EMG
SRESA+
start/reset
SRESA-
B-axis EMG
SRESB+
start/reset
SRESB-
A-axis SDO2
SDO2A+
SDO2A-
B-axis SDO2
SDO2B+
SDO2B-
Control circuit
+24V
power supply
Control circuit
0V
power GND
A-axis STO state
TOFA
B-axis STO state
TOFB
App. 5.8.2 Interfaces
In this servo amplifier, source type I/O interfaces can be used.
(1) Sink I/O interface (CN9, CN10 connector)
(a) Digital input interface DI-1
This is an input circuit whose photocoupler cathode side is the input terminal.
Transmit signals from sink (open-collector) type transistor output, relay switch, etc.
Pin No.
3A
Connect this device to a safety switch for A-axis driving device.
3B
Input the same signal as A-axis shutdown 1.
STO state (base shutdown): Open between SDI2A+ and SDI2A-.
STO release state (in driving): Close between SDI2A+ and SDI2A-.
4A
Connect this device to a safety switch for B-axis driving device.
4B
Input the same signal as B-axis shutdown 1.
STO state (base shutdown): Open between SDI2B+ and SDI2B-.
STO release state (in driving): Close between SDI2B+ and SDI2B-.
1A
Signal for releasing STO state (base shutdown) on A-axis driving device.
1B
Releases STO state (base shutdown) on A-axis driving device by switching between
SRESA+ and SRESA- from on (connected) to off (opened).
2A
Signal for releasing STO state (base shutdown) on B-axis driving device.
2B
Releases STO state (base shutdown) on B-axis driving device by switching between
SRESB+ and SRESB- from on (connected) to off (opened).
6A
Outputs STO2 to A-axis driving device.
6B
Outputs the same signal as A-axis STO1.
STO state (base shutdown): Between SDO2A+ and SDO2A- is opened.
STO release state (in driving): Between SDO2A+ and SDO2A- is closed.
5A
Outputs STO2 to B-axis driving device.
5B
Outputs the same signal as B-axis SDO1.
STO state (base shutdown): Between SDO2B+ and SDO2B- is opened.
STO release state (in driving): Between SDO2B+ and SDO2B- is closed.
7A
Connect + side of 24 V DC.
7B
Connect - side of 24 V DC.
8A
TOFA is internally connected with TOF2A.
8B
TOFB is internally connected with TOF2B.
For transistor
Approximately
5 mA
TR
V
1.0 V
CES
I
100 µA
CEO
App. - 28
Function/Application
MR-J3-D05
SRESA-,
etc.
About 5.4 kΩ
Switch
SRESA+,
etc.
24 V DC ± 10%
200 mA
I/O
division
DI-1
DI-1
DI-1
DI-1
DO-1
DO-1

Hide quick links:

Advertisement

Table of Contents
loading