5. Set up Other Functions

Adjusting the squelch level

z When the squelch level is set to "open" the repeater will transmit, so the TX output must be connected to the duplexer
and antenna.
z Use extreme caution when making the squelch adjustment or measurement with a signal generator. Do not connect
the signal generator to the duplexer antenna port. To avoid damage to the test equipment, always connect the signal
generator directly to the RX antenna connector on the DR-2X/DR-2XE.
z While the squelch level is being set, repeater transmit operation is temporarily permitted. This will facilitate checking
the performance of the Duplexer, and allow evaluation of the receiver sensitivity degradation ("desense"), during
simultaneous transmit/receive operation.
1 Touch [ A SETUP ] or [ B SETUP ] .
The setup mode screen will appear.
2 Touch [ SQL ] .
When [ SQL ] turns yellow, the VOL meter below the RX band frequency
display, will change to the SQL meter and show the squelch level
setting.
3 Touch [ ▲ ] or [ ▼ ] to adjust the squelch level.
The level will be displayed in the SQL meter.
4 Touch [ BACK ] .
The squelch level is set, and the display will return to the operation
mode screen.

Adjusting the transmit power

1 Touch [ A SETUP ] or [ B SETUP ] .
The setup mode screen will appear.
2 Touch [ Tx PWR ] to select the transmit power.
The setting is changed in the following sequence, each time
[ Tx PWR ] is touched.
"HI" à "LO" à "MD" à
HI
MD
50 W
20 W
3 Touch [ BACK ] .
The transmit power level is set, and the display will return to the
operation mode screen.

Adjusting the volume

Turn the VOL knob.
The VOL knob adjusts the audio volume level of the received (uplink) signal.

Turning the display ON and OFF

1
Press and hold the SETUP button to turn the display OFF.
When a display is OFF, operation of the touch panel will be locked.
The display will turn OFF automatically after a period of time (default 1
min) with no operation.
The display duration time setting may be selected from "1min", "5min",
"10min", or "30min" (see page 38 "Setting the display turn-off time").
2
Press and hold the SETUP button for 3 seconds to turn the display
ON.