Remote Operation With External Controller - Yaesu DR-2X Operating Manual

Vhf/uhf c4fm/fm 50 ams digital repeater
Hide thumbs Also See for DR-2X:
Table of Contents

Advertisement

19. Remote Operation with External Controller

Repeater operation may be controlled remotely by connecting an external controller through the [ CONTROL
I/O ] connector at the back of the repeater.
The following features are available while in remote operation:
Change the communication mode of repeater transmit and receive
Turn the RX and TX tone signal "ON" or "OFF"
Monitor the discriminator analog or demodulated digital audio during up-link reception
To use the repeater under remote control, set up the repeater as explained below, after it is connected to the
external controller.
Turning remote operation ON/OFF
When the remote operation is "ON", the repeater operates according to the control instructions received from
the external controller (the instructions are received through Pin 11 to Pin 14 of the [ CONTROL I/O ] connector).
When the remote operation is "OFF", the repeater operates according to the settings determined through the
setup mode.
1 Touch [ A SETUP ] .
The setup mode screen will appear.
2 Touch [ F ] .
The setup menu will appear.
3 Touch [ MODE/REMOTE ] .
The menu list will appear.
4 Touch [ REMOTE ] .
The set value will change between [ OFF ] and [ ON ] each time
[ REMOTE ] is touched.
z Factory default: OFF
z Remote operation is available only on the CH-A.
z Remote operation is not available in the "HRI + REPEATER MODE".
5 Touch [ BACK ] 3 times.
The setting is determined and the display will return to the operation mode screen.
Note that [ REMOTE ] at the bottom left of the screen is displayed in red.
z It can repeat only in FM FIX / FM FIX mode by the external controller.
z In the FM FIX / Digital FIX mode, audio of the uplink cannot repeat; but the audio input signal from the external
controller can transmit in digital mode by external PTT on.
z You can transmit by the microphone and PTT input of the front panel in all settings except AMS/AMS.
Control from external controller
To control the DR-2X/DR-2XE remotely, optional cables can be used
to connect the repeater to an external controller.
Use the "CONTROL I/O" connector at the back of the repeater to con-
nect with the external controller.
To interface the DR-2X/DR-2XE with an external controller, additional
cables with a 15-pin mini d-sub connector are needed to connect to
the "CONTROL I/O" connector. Your controller may also require rewir-
ing.
Link operation may require four connections: receiver audio, transmit-
ter audio, receiver COR, and transmitter PTT; however, these are not
available on the "CONTROL I/O" connector.
The pin assignment of the "CONTROL I/O" connector is as follows.
Do not use a VGA cable for PC display to connect the external controller
to the repeater.
42
REMOTE/COMMAND/DISP TIMER
REMOTE
COMMAND
DISPLAY TIMER
V
/
M
BACK
BACK
CONTROL I/O connector
(as viewed from real panel)
DR-2X / DR-2XE Operating Manual
ON
>
ON
5~1
10~6
15~11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dr-2xe

Table of Contents