Hitachi VSP G200 System Administration Manual page 181

Virtual storage platform gx00 and fx00
Hide thumbs Also See for VSP G200:
Table of Contents

Advertisement

Operation name
Edit Ports
Add Remote Connection
Edit Remote Connection
Options
Create Pairs
Split Pairs
Resync Pairs
Delete Pairs
Edit Pair Options
Add Remote Paths
Remove Remote Paths
Edit Remote Connection
Options
Remove Remote
Connections
Force Delete Pairs
Access requirements for global-active device
The following table specifies the resource access requirements for global-
active device operations.
Operation name
Edit Ports
Add Remote Connection
Edit Remote Connection
Options
Create Pairs
Split Pairs
Resync Pairs
Delete Pairs
System Administrator Guide for VSP Gx00 models and VSP Fx00 models
Specified ports must be assigned to the user.
Specified initiator ports must be assigned to the user.
Operation can be performed with no conditions.
Primary volumes must be assigned to the user.
Initiator ports of remote paths that are connected with the primary
volume in the remote storage must be assigned to the user.
Specified primary volumes or secondary volumes must be assigned
to the user.
Primary volumes must be assigned to the user.
Specified volumes must be assigned to the user.
If primary volumes are specified, the initiator ports of remote paths
that are connected with the primary volume in the remote storage
must be assigned to the user.
Primary volumes must be assigned to the user.
Specified initiator ports must be assigned to the user.
Specified initiator ports must be assigned to the user.
Initiator ports of remote paths that are connected to a specified
remote storage must be assigned to the user.
Initiator ports of remote paths that are connected to a specified
remote storage must be assigned to the user.
Specified primary volumes or secondary volumes must be assigned
to the user.
Specified ports must be assigned to the user.
Specified initiator ports must be assigned to the user.
Operation can be performed with no conditions.
Primary volumes must be assigned to the user.
Initiator ports of remote paths that are connected with the primary
volume in the remote storage must be assigned to the user.
Specified primary volumes or secondary volumes must be assigned
to the user.
Primary volumes must be assigned to the user.
Specified volumes must be assigned to the user.
User administration
Condition
Condition
181

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vsp g400Vsp f600Vsp g800Vsp g600Vsp f800Vsp f400

Table of Contents