Hitachi G370 Hardware Reference Manual

Virtual storage platform
Hide thumbs Also See for G370:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform G350 and
G370
x
88-03-2
Hardware Reference Guide
This document provides information about the system hardware components and the mechanical and
environmental specifications for the Hitachi Virtual Storage Platform G350 and G370 storage systems.
MK-97HM85012-03
November 2019

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi G370

  • Page 1 Hitachi Virtual Storage Platform G350 and G370 88-03-2 Hardware Reference Guide This document provides information about the system hardware components and the mechanical and environmental specifications for the Hitachi Virtual Storage Platform G350 and G370 storage systems. MK-97HM85012-03 November 2019...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    10-Gbps iSCSI board LEDs and connectors (copper)......27 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors..................28 16-Gbps Fibre Channel (2-port) board LEDs and connectors....30 Back-end module LEDs and connectors............31 Contents Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 4 Data and power cable model list................66 Appendix B: System specifications ........... 69 VSP G350 mechanical specifications..............69 VSP G370 mechanical specifications..............75 Electrical specifications ..................81 Environmental specifications ................82 Shared memory....................89 Contents Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 5 Hitachi Universal V2 Rack accessories............127 Third-party rack support for DB60 dense intermix drive trays......127 Appendix G: Warning labels on the storage system....... 129 CBSS controller....................130 CBSL controller....................131 Contents Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 6 Dense intermix drive tray................. 134 CBSS/CBSL controller..................135 Dense intermix drive tray power supply............135 CMA (used to secure dense intermix drive tray)..........136 Battery......................136 Appendix H: Environmental notices..........137 Appendix I: Regulatory compliance..........138 Contents Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 7: Preface

    Preface This guide describes the hardware features and specifications of the Hitachi Virtual Storage Platform G350 and G370 (VSP Gx00 models). Intended audience This document is intended for Hitachi Vantara representatives, system administrators, authorized service providers, or customers who install, configure, and operate the VSP Gx00 models.
  • Page 8: Product Version

    ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Product version This document revision applies to VSP G350, G370 firmware 88-03-2x or later. Release notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document.
  • Page 9 Indicates required or expected values. Example: { a | b } indicates that you must choose either a or b. | vertical bar Indicates that you have a choice between two or more options or arguments. Examples: Preface Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 10: Conventions For Storage Capacity Values

    1,000 TB or 1,000 bytes 1 exabyte (EB) 1,000 PB or 1,000 bytes Logical capacity values (for example, logical device capacity, cache memory capacity) are calculated based on the following values: Preface Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 11: Accessing Product Documentation

    Getting help Hitachi Vantara Support Connect is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to Hitachi Vantara Support Connect for contact information: https://support.hitachivantara.com/en_us/ contact-us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
  • Page 12: Comments

    Please send us your comments on this document to doc.comments@hitachivantara.com. Include the document title and number, including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Vantara Corporation. Thank you! Preface...
  • Page 13: Chapter 1: Overview

    Chapter 1: Overview The Hitachi Virtual Storage Platform G350 and VSP G370 is a versatile modular, rack- mountable hybrid array storage system equipped with drive boxes, supporting SAS hard- disk drives and flash drives, scaled for various storage capacity configurations.
  • Page 14 High-density intermix drive tray (DB60): Up to 60 3.5-inch HDDs can be installed (4U ■ size) Supports system environments with mixed operating systems such as UNIX, Linux, ■ Windows, and VMware Chapter 1: Overview Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 15: Chapter 2: System Controllers

    Each controller includes the following internal components such as a processor, dual in- line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator. If the data path through one controller fails, all drives remain available to data hosts using a redundant data path through the other controller.
  • Page 16 /en_us/contact-us.html. POWER ON/OFF ( main Powers the storage system. switch) Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 17: Cbss Controller Front Panel Leds (Without Bezel)

    The slots are organized from 0 to 23. CBSS controller rear panel LEDs The following table lists the descriptions of the CBSS controller rear panel LEDs. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 18 Cache flash memory LAN-RST switch Use only when instructed by customer support. LAN port Maintenance LAN port (left) and user LAN port (right). Uninterruptible power supply (UPS) port Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 19: Cbss Controller Power Supply Unit Leds And Connectors

    Power supply unit CBSS controller power supply unit LEDs and connectors The following table describes the definitions of the CBSS controller AC power supply unit LEDs and connectors. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 20: Controller Chassis With Large Form-Factor Drive Bays (Cbsl)

    LEDs located on the front and rear of controller to provide its operating status. The following table lists the controller board specifications. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 21: Cbsl Controller Front Panel Bezel Leds

    Green: Storage system is powered on. Amber: Storage system is receiving power. READY LED Green: Normal operation WARNING LED Off: Normal operation. Amber: Component requires maintenance. Blink: Failure requires maintenance. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 22: Cbsl Controller Front Panel Leds (Without Bezel)

    CBSL controller front panel LEDs (without bezel) The following table describes the definitions of the CBSL controller front panel LEDs. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 23: Cbsl Controller Rear Panel Leds

    The slots are organized in the following order: CBSL controller rear panel LEDs The following table describes the definitions of the CBSL controller rear panel LEDs. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 24 Backup module STATUS Green: Charging of the battery in the backup module is complete. Blink green: Battery in the backup module is charging or discharging. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 25: Cbsl Controller Ac Power Supply Unit Leds And Connectors

    AC IN LED Blue: AC input is normal. ALM / RDY LED Red: Power supply unit can be replaced. Green: Normal operation. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 26: Host, Network, And Drive Tray Ports And Leds

    Red: Front end module can be removed safely. PORT LED Red: Small form-factor pluggable can be removed. Blue: Normal link status. Blink blue: Front end module is in communication status. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 27: 10-Gbps Iscsi Board Leds And Connectors (Copper)

    PORT LED Green: Link connection is established. Blinking: Communication is in progress. Off: No link connection or not ready to communicate. ISCSI connectors Connect to Ethernet cables. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 28: 8-Gbps, 16-Gbps, Or 32-Gbps Fibre Channel (4-Port) Board Leds And Connectors

    Description Fibre Channel connectors Connect to Fibre Channel cables. STATUS LED Green: Front end module is in power-on state. Red: Front end module can be removed safely. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 29 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel ports (left to right) CHB number Port 1 Port 2 Port 3 Port 4 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 30: 16-Gbps Fibre Channel (2-Port) Board Leds And Connectors

    Red: Small form-factor pluggable can be removed. Blue: Normal link status at 16-Gbps. Green: Normal link status at 4-Gbps or 8-Gbps. Fibre Channel connectors Connect to Fibre Channel cables. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 31: Back-End Module Leds And Connectors

    CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H Back-end module LEDs and connectors The back-end module LEDs display the operating status of the module. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 32 Back-end module LEDs and connectors Number Item Description PATH 1 connector Connects to a drive tray. PORT LED Blue: Normal link status. Chapter 2: System controllers Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 33: Chapter 3: Drive Trays

    2U (88.2 mm) 2.5 inch (SFF) SFF with front panel bezel Number Item Description POWER LED Green: Drive tray is powered on. READY LED Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 34: Sff Front Panel Without Bezel

    Can be turned on or ■ turned off by the maintenance utility. ALM LED Red: Drive stopped due to a failure and can be replaced. ACT LED Green: Normal operation. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 35: Sff Rear Panel

    ALARM LED Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 36: Ac Power Supply Unit Leds And Connectors

    LEDs to display its operating status. Number Item Description RDY LED Green: Normal operation. ACI IN LED Green: AC input is operating normally. ALM LED Red: Power supply unit can be replaced. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 37: Large Form-Factor Drive Tray (Dbl)

    Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 38: Lff Front Panel Without Bezel

    Large form-factor drives The twelve 3.5-inch large form factor drives are positioned horizontally. The slots are organized in the following order: Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 39: Lff Rear Panel

    Connects to the power cable provided with the storage system. AC IN LED Green: Normal operation. ALM LED Red: Power supply unit can be replaced. RDY LED Green: Normal operation. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 40: Ac Power Supply Unit Leds And Connectors

    The following describes the physical specifications of the high-density drive tray. Number of Name Model name Height drive slots Drive type DB60 DW-F800- 4U (176 mm) 3.5 inch (LFF) DB60C Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 41: Dense Intermix Drive Tray With Front Panel Bezel

    Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 42: Dense Intermix Drive Tray Display Leds

    On the left side of the preceding figure, the rear of the drive tray is at the top. Rear of drive tray: 48-59 ■ 36-47 ■ 24-35 ■ 12-23 ■ Front of drive tray: 00-11 ■ Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 43: Dense Intermix Drive Tray Rear Panel

    Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Console This port is reserved. ALARM LED Red: ENC can be replaced. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 44 Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 45: Chapter 4: Service Processor

    The SVP is also available as a 64-bit software application provided by Hitachi Vantara. For the latest interoperability updates and details, see the SVP (Service Processor) OS and Hypervisor support report at https://support.hitachivantara.com/en_us/...
  • Page 46: Service Processor Description

    <model number><system serial number>/emergency.do. For example: Storage system model Storage system serial number number 8320004 456789 http://192.168.0.15/dev/ storage/8320004456789/ emergency.do 8340004 456789 http://192.168.0.15/dev/ storage/8340004456789/ emergency.do 8360004 456789 http://192.168.0.15/dev/ storage/8360004456789/ emergency.do Chapter 4: Service processor Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 47: Svp (Windows 10 Enterprise) Front Panel

    Turning on automatic Windows updates or using the manual Windows update ■ method. Installing antivirus software that has been tested and approved by Hitachi. ■ SVP (Windows 10 Enterprise) front panel The front panel of the physical SVP with Windows 10 Enterprise operating system is equipped with LEDs, a reset button, and a power button.
  • Page 48 After the Initial Startup Wizard is complete, the SVP can be used in non-bridge mode. In this mode, the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches. For more information, contact customer support. Chapter 4: Service processor Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 49: Chapter 5: Maintaining The Storage System

    To avoid this situation, charge the battery for more than three hours at least once every six months. Chapter 5: Maintaining the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 50: Battery Unit

    Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Chapter 5: Maintaining the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 51 SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Chapter 5: Maintaining the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 52: Appendix A: Storage System Parts List

    Appendix A: Storage system parts list The following parts list describes the standard and optional hardware components for the storage systems. For more information about the storage system, contact an Hitachi Vantara sales representative. VSP G350 parts list The VSP G350 includes the following standard and optional components.
  • Page 53 3.8 TB, MLC/TLC, 12 Gbps, 0-24 SFF, flash drive DKC-F810I-7R6MGM 7.6 TB, TLC, 12 Gbps, SFF, 0-24 flash drive DKC-F810I-15RMGM 15 TB, TLC, 12 Gbps, SFF, 0-24 flash drive Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 54 Model number Part description Quantity DW800-CBSL 2U chassis AC power supply unit Backup module (BKM) Front bezel (2U) Binder SAS cable label DW-F800-RRCB Rail kit Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 55 SFP for 32 Gbps Longwave 0-16 Note: 1. A DIMM of a particular capacity cannot be mixed with different capacities in a storage system configuration. Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 56 3.8 TB, MLC/TLC, 12 Gbps, 0-24 SFF, flash drive DKC-F810I-7R6MGM 7.6 TB, TLC, 12 Gbps, SFF, 0-24 flash drive DKC-F810I-15RMGM 15 TB, TLC, 12 Gbps, SFF, 0-24 flash drive Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 57 DW-F800-DB60C 4U chassis Power supply unit Front bezel (DB60 drive chassis) Rail kit (including CMA) (DW-F800-RRDB60) SAS cable (3m), including 2 omega clips (DW-F800- SCQ3) Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 58: Drive Tray And Drive Configuration

    Number of mountable drive trays Maximum number of mountable drives Flash Controller Solid-state module chassis Drive trays Maximum SAS drive drive drive (FMD) CBSS DB60 CBSL DB60 Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 59: Vsp G370 Parts List

    VSP G370 parts list VSP G370 parts list The VSP G370 includes the following standard and optional components. Table 16 CBSS controller components Model number Part description Quantity DW800-CBSS 2U chassis AC power supply unit Backup module (BKM) Front bezel (2U)
  • Page 60 3.8 TB, MLC/TLC, 12 Gbps, 0-24 SFF, flash drive DKC-F810I-7R6MGM 7.6 TB, TLC, 12 Gbps, SFF, 0-24 flash drive DKC-F810I-15RMGM 15 TB, TLC, 12 Gbps, SFF, 0-24 flash drive Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 61 Model number Part description Quantity DW800-CBSL 2U chassis AC power supply unit Backup module (BKM) Front bezel (2U) Binder SAS cable label DW-F800-RRCB Rail kit Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 62 SFP for 32 Gbps Longwave 0-16 Note: 1. A DIMM of a particular capacity cannot be mixed with different capacities in a storage system configuration. Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 63 3.8 TB, MLC/TLC, 12 Gbps, 0-24 SFF, flash drive DKC-F810I-7R6MGM 7.6 TB, TLC, 12 Gbps, SFF, 0-24 flash drive DKC-F810I-15RMGM 15 TB, TLC, 12 Gbps, SFF, 0-24 flash drive Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 64 DW-F800-DB60C 4U chassis Power supply unit Front bezel (DB60 drive chassis) Rail kit (including CMA) (DW-F800-RRDB60) SAS cable (3m), including 2 omega clips (DW-F800- SCQ3) Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 65: Drive Tray And Drive Configuration

    Number of mountable drive trays Maximum number of mountable drives Flash Controller Solid-state module chassis Drive trays Maximum SAS drive drive drive (FMD) CBSS DB60 CBSL DB60 Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 66: Data And Power Cable Model List

    5 m SAS cable, including omega clips (2) DW-F800-SCQ10A 10 m SAS optical cable DW-F800-SCQ30A 30 m SAS optical cable DW-F800-SCQ1HA 100 m SAS optical cable Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 67 30 m LC-LC optical cable for optical A-6515-JM50L 50 m LC-LC optical cable for optical A-6515-JM100L 100 m LC-LC optical cable for optical A-6515-JM200L 200 m LC-LC optical cable for optical Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 68 Data and power cable model list Model number Specification A-6515-JM300L 300 m LC-LC optical cable for optical Appendix A: Storage system parts list Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 69: Appendix B: System Specifications

    483 × 813 × 88 mm (W x D x H) (mm) Weight/Mass (kg) 16.1 kg (CBSS) (Approximate) 15.9 kg (CBSL) Start-up time (min) 5 to 8 (min) Required height Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 70 DB60 482 × 1,029 × 176 mm Weight/Mass (kg) 17 kg (Approximate) 17.4 kg DB60 36 kg Start-up time (min) 5 to 8 (min) DB60 Required height Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 71 2. Can be mounted on the RKU rack. For the mounting, special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems. 3. The value is at maximum level. Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 72 (unit) may vary. 2. Available as spare or data disks. Host interface Item Specification Interface type 16/32 Gbps FC (Optical) 10 Gbps iSCSI (Optical) Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 73 Up to 104º (40º C) 3 years 2 years RAID specifications Item Specification RAID level SAS/SAS7.2K/Flash drive mounted: 1/5/6 RAID configuration RAID1: 2D+2D, 4D+4D RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 74 L3 cache memory: 4 MB SDRAM: 1 GB Data assurance method Data bus: Parity Cache memory: ECC (1 bit correction, 2 bit detection) Drive: Data assurance code Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 75: Vsp G370 Mechanical Specifications

    Insulation withstand voltage AC 1,500 V (100mA, 1min) Insulation resistance DC 500 V, 10 MΩ or more VSP G370 mechanical specifications The following tables list the system specifications for VSP G370. CBSS/CBSL controller chassis Item Specification Physical dimension 483 × 813 × 88 mm...
  • Page 76 DB60 482 × 1,029 × 176 mm Weight/Mass (kg) 17 kg (Approximate) 17.4 kg DB60 36 kg Start-up time (min) 5 to 8 (min) DB60 Required height Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 77 2. Can be mounted on the RKU rack. For the mounting, special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems. 3. The value is at maximum level. Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 78 (unit) may vary. 2. Available as spare or data disks. Host interface Item Specification Interface type 16/32 Gbps FC (Optical) 10 Gbps iSCSI (Optical) Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 79 Up to 104º (40º C) 3 years 2 years RAID specifications Item Specification RAID level SAS/SAS7.2K/Flash drive mounted: 1/5/6 RAID configuration RAID1: 2D+2D, 4D+4D RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 80 L3 cache memory: 4 MB SDRAM: 1 GB Data assurance method Data bus: Parity Cache memory: ECC (1 bit correction, 2 bit detection) Drive: Data assurance code Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 81: Electrical Specifications

    Number of phases, cabling Single-phase with protective grounding Steady-state current 100V/ CBSS: 4.0x2/2.0x2 SFF drive tray: 2.4x2/1.2x2 200V CBSL: 4.0x2/2.0x2 LFF drive tray: 1.9x2/1.0x2 Dense intermix drive tray: -/3.0x2 Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 82: Environmental Specifications

    . The actual required power might exceed the value shown in the table when the tolerance is included. Environmental specifications The environmental specifications for the storage systems are described in the following table. Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 83 5 to 95 Maximum wet bulb 29°C (non-condensing) temperature (°C) Vibration CBSS/CBSL DBS, DBL drive State controller trays DB60 drive tray Operating 2.5 or less (5 to 300Hz) Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 84 (10 ms, half sine wave) Transport 80 or less (packed) (m/s Tipping angle 15° or less (°) (To be measured when installed on leveling bolts.) (Storage system tips over) Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 85 Operating Gaseous contamination should be within ANSI/ISA S71.04-2013 G1 classification levels. Non-operating Recommends the data centers maintain a clean operating environment by monitoring and controlling gaseous contamination. Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 86 Therefore, the rate of the noise occupied by high-frequency content is high. Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 87 The acoustic noise level of 90 dB or less in the operating environment table represents the current operating environment guidelines in which Hitachi storage systems are designed and manufactured for reliable operation when placed 2 meters from the source of the noise.
  • Page 88 Environmental specifications State Condition Hitachi does not test storage systems and data drives (includes HDDs, SSDs, and FMDs) for compatibility with fire suppression systems and pneumatic sirens. Hitachi also does not provide recommendations or claim compatibility with any fire suppression systems and pneumatic sirens.
  • Page 89: Shared Memory

    9.8m/s (1.0G) equivalent to NEBS (Network Equipment-Building System) Level3). Shared memory Using Hitachi software products, the number of pairs, migration plans, and pool capacities and virtual volumes depend on the amount of capacity of shared memory installed on the controller.
  • Page 90 Table 32 Minimum cache memory capacity required for shared memory function Shared Memory Function VSP G350 VSP G370 Base 64 GiB 128 GiB Extension1 128 GiB 128 GiB Extension2 128 GiB 256 GiB Extension3 Appendix B: System specifications Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 91: Appendix C: Network Access

    Review the following ports before you install the storage system to avoid conflicts between the TCP/IP port assignments used by the storage system and those used by other devices and applications. Appendix C: Network access Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 92 Interface (CCI) data collection procedures. 34001 Used by RAID Manager. 51099 Used by Device Manager - Storage Navigator for communication. 51100 Used by Device Manager - Storage Navigator for communication. Appendix C: Network access Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 93 S is not used. or later Automatic 88-02-0x -xx/00 allocation or later CommonJettySt HTTP 8080 88-02-0x -xx/00 or later CommonJettySt HTTP 8210 RestAPIServerS HTTP 9210 DeviceJettyStart HTTP 8081 Appendix C: Network access Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 94: Controller Connections

    ■ Physical service processor connections The SVP is available as an optional, physical device provided by Hitachi Vantara or as a virtual guest host running on customer-provided ESX servers and VM/OS licenses and media. The SVP provides error detection and reporting and supports diagnostic and maintenance activities involving the storage system.
  • Page 95 SVP Guest OS (1 DKC) Windows 10 IoT Enterprise ■ 2 x vCPU ■ 1 virtual network adapter ■ 4 GB RAM ■ 120 GB disk space ■ Appendix C: Network access Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 96: Appendix D: Data And Power Cables

    Serial-attached SCSI (SAS) cables are used to connect drive trays to controllers and other drive trays. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 97 Fibre Channel cable length based on cable size and port speed. Cable size Speed Maximum cable length 9 micron 1 Gbps 1 km (3281 ft) 2 Gbps 2 km Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 98: Fibre Channel Cables

    Note: Due to high-speed serial data transfer via Fibre Channel, use high- quality FC cables that comply with the Fibre Channel-PH standard. The following figure shows FC direct connection and FC connection through a switch. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 99 114.8 ft (35 m) 328.08 ft (100 410.1 ft (125 m) — 32 Gbps 65.62 ft (20 m) 229.7 ft (70 m) 328.08 ft (100 — Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 100 (OMx) 850 nm LC-LC cable DXLC-2PS- 9/125 μm (longwave) SPC-xxM- Singlemode Wavelength: 10/125-2SR 1300 nm The following figure shows the connector used for optical interfaces. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 101: Iscsi Cables

    Cable One side Other side LC-LC cable Optical Equivalent 50, 125 mm to DXLC-2P- Multimode connector connector PC-xxM- Wavelength: GC50, 850 nm 125-2SR (OMx) Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 102 LC connector type ■ Connector type: LC duplex receptacle connector ■ Interval: 6.25 mm flat type, two rows ■ Cable specifications for 10 Gbps iSCSI copper interface Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 103 10 Gbps 10GBASE-T STP ( use an RJ-45 LAN cable STP cable that suppresses radio noise) The following figure shows a 10 Gbps iSCSI cable. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 104: Iscsi Standards

    255 (maximum per iSCSI With Linux software port) initiator, the maximum number decreases. Path failover HDLM Supports Microsoft MPIO (Multi Path I/O) Link 10 Gbps SFP+ Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 105 Port IPv6 is set to Enabled, verify the IPv6 router is connected to the same network, and then set IPv6 global address automatically. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 106 Supported Detects header error or data error with iSCSI communication. The storage system follows the host's digest setting. If digest is enabled, the performance degrades. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 107: Managing Cables

    ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef Managing cables Organize cables to protect the integrity of your connections and allow proper airflow around your storage system. Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 108 40 mm (1.73 inch) iSCSI optical 40 mm (1.73 inch) Category 5 Ethernet Four times the outside diameter of the cable 40 mm (1.73 inch) Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 109 Cabling full-width modules When cabling full-width modules, route the cables horizontally, so that they do not interfere when replacing a module. Ensuring adequate airflow Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 110: Ac Power Cables

    ■ AC power cables Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended.
  • Page 111 South Africa 200-240 10, 16 SABS-164 Switzerland 200-240 SEV 1011 International 200-240 IEC 309 United 200-240 BS-1363 Kingdom International 200-240 IEC 309 International 200-240 IEC 309 Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 112: Ac Connections

    3 IEC 83 NEMA L6-20P 200V-240V 1 ANSI C73.11 2 NEMA 6-15P 3 IEC 83 CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 113 AC connections Reference Description Receptacle Input rating standards BS-1363 200V-240V 5 BS 1365 3 IEC 83 AS-3112 200V-240V 6 AS C112 Cable and connector Appendix D: Data and power cables Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 114: Power Cable Usage Guidelines

    Power cable usage guidelines Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: Type of AC line feed provided by the facility.
  • Page 115: Appendix E: Power Distribution Units For Hitachi Universal V2B Rack

    Balance the electrical current load between available PDUs. ■ Americas single-phase PDU 1P30A-8C13-3C19UL.P The following figure and table describe the specifications of the PDU. Figure 1 Americas PDU for the Hitachi Universal V2B Rack (Single-phase PDU 1P30A-8C13-3C19UL.P) Power Total rack...
  • Page 116: Americas Single-Phase Pdu 1P30A-15C13-3C19Ul.p

    4.5 m (14.76 feet) cable Americas single-phase PDU 1P30A-15C13-3C19UL.P The following figure and table describe the specifications of the PDU. Figure 2 Americas PDU for the Hitachi Universal V2B Rack (Single-phase PDU 1P30A-15C13-3C19UL.P) Power Total rack Part Power input...
  • Page 117: Americas Three-Phase Pdu 3P30A-8C13-3C19Ul.p

    Americas three-phase PDU 3P30A-8C13-3C19UL.P Americas three-phase PDU 3P30A-8C13-3C19UL.P The following figure and table describe the specifications of the PDU. Figure 3 Americas PDU for the Hitachi Universal V2B Rack (Three-phase PDU 3P30A-8C13-3C19UL.P) Power Total rack Part Power input output per...
  • Page 118: Americas Three-Phase Pdu 3P30A-24C13-6C19Ul.p

    Americas three-phase PDU 3P30A-24C13-6C19UL.P Figure 4 Americas PDU for the Hitachi Universal V2B Rack (Three-phase PDU 3P30A-15C13-3C19UL.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 3P30A-15C Americas 4/rack Three phase 15 IEC C13 77A (16kVA) 13-3C19UL.
  • Page 119: Apac And Emea Single-Phase Pdu 1P32A-9C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-9C13-3C19CE.P Figure 5 Americas PDU for the Hitachi Universal V2B Rack (Three-phase PDU 3P30A-24C13-6C19UL.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 3P30A-24C Americas 2/rack Three phase 24 IEC C13 38.4A (8kVA)
  • Page 120: Apac And Emea Single-Phase Pdu 1P32A-18C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-18C13-3C19CE.P Figure 6 APAC and EMEA PDU for the Hitachi Universal V2B Rack (Single-phase 1P32A-9C13-3C19CE.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 1P32A-9C1 APAC and 6/rack Single phase 9 IEC C13 + 77A (17.6kVA)
  • Page 121: Apac And Emea Three-Phase Pdu 3P16A-9C13-3C19Ce.p

    APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P Figure 7 APAC and EMEA PDU for the Hitachi Universal V2B Rack (Single-phase 1P32A-18C13-3C19CE.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 1P32A-18C APAC and 4/rack Single phase 18 IEC C13 77A (17.6kVA)
  • Page 122: Apac And Emea Three-Phase Pdu 3P16A-15C13-3C19Ce.p

    APAC and EMEA three-phase PDU 3P16A-15C13-3C19CE.P Figure 8 APAC and EMEA PDU for the Hitachi Universal V2B Rack (Three-phase 3P16A-9C13-3C19CE.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 3P16A-9C1 APAC and 6/rack Three phase 9 IEC C13 + 115A (26.4kVA)
  • Page 123: Apac And Emea Three-Phase Pdu 3P32A-24C13-6C19Ce.p

    APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P Figure 9 APAC and EMEA PDU for the Hitachi Universal V2B Rack (Three-phase 3P16A-15C13-3C19CE.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 3P16A-15C APAC and 4/rack Three phase 15 IEC C13 77A (17.6kVA)
  • Page 124: Americas, Apac, And Emea Three-Phase Pdu 3P30A-243-69Ce-Ul.p

    Americas, APAC, and EMEA three-phase PDU 3P30A-243-69CE-UL.P Figure 10 APAC and EMEA PDU for the Hitachi Universal V2B Rack (Three-phase 3P32A-24C13-6C19CE.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 3P32A-24C APAC and 2/rack...
  • Page 125 Americas, APAC, and EMEA three-phase PDU 3P30A-243-69CE-UL.P Figure 11 APAC and EMEA PDU for the Hitachi Universal V2B Rack (Three-phase 3P30A-243-69CE-UL.P) Power Total rack Part Power input output per amperage number Region Quantity per PDU available 3P30A-243- Americas, 2/rack Three phase 24 IEC C13 77A (17.6kVA)
  • Page 126: Appendix F: Non-Hitachi Racks

    PDUs and cable loops. Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
  • Page 127: Hitachi Universal V2 Rack Accessories

    Dense tray rail kits require square mounting holed racks. ■ Use a ladder to service the DB60 dense intermix drive tray if the drive tray is mounted ■ above shelf height RU32. Appendix F: Non-Hitachi racks Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 128 Third-party rack support for DB60 dense intermix drive trays Appendix F: Non-Hitachi racks Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 129: Appendix G: Warning Labels On The Storage System

    Use caution when handling equipment with movable parts. Use caution when handling equipment with hot surfaces. Use caution when handling equipment prone to tipping over. Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 130: Cbss Controller

    CBSS controller CBSS controller Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 131: Cbsl Controller

    CBSL controller CBSL controller Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 132: Small Form Factor Drive Tray

    Small form factor drive tray Small form factor drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 133: Large Form Factor Drive Tray

    Large form factor drive tray Large form factor drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 134: Dense Intermix Drive Tray

    Dense intermix drive tray Dense intermix drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 135: Cbss/Cbsl Controller

    CBSS/CBSL controller CBSS/CBSL controller Dense intermix drive tray power supply Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 136: Cma (Used To Secure Dense Intermix Drive Tray)

    CMA (used to secure dense intermix drive tray) CMA (used to secure dense intermix drive tray) Battery Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 137: Appendix H: Environmental Notices

    They will dispose of it for you. This nickel-metal hydride battery, which is designated as recycling product by a recycling promotion low, must be recycled. The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part. Appendix H: Environmental notices Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 138: Appendix I: Regulatory Compliance

    Appendix I: Regulatory compliance This equipment has been tested and certified for compliance with the following standards. Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 139 All CB countries 1+A2 IEC60950-1:2005+A S_Mark Argentina 1+A2 TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan EN60950-1:2006+A1 CE marking 1+A1+A12+A2 Radio interference VCCI V-3/2015.4 VCCI Japan voluntary control Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 140 This is a class A product. In a domestic environment this product can cause radio interference in which case the user can be required to take adequate measures. Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide...
  • Page 141 Hitachi Vantara Corporate Headquarters Contact Information 2535 Augustine Drive USA: 1-800-446-0744 Santa Clara, CA 95054 USA Global: 1-858-547-4526 HitachiVantara.com | community.HitachiVantara.com HitachiVantara.com/contact...

This manual is also suitable for:

Virtual storage platform g350Virtual storage platform g370Vsp g370Vsp g350