Hitachi VSP N400 Hardware Reference Manual
Hitachi VSP N400 Hardware Reference Manual

Hitachi VSP N400 Hardware Reference Manual

Virtual storage platform
Table of Contents

Advertisement

Hitachi Virtual Storage Platform N400, N600
83-06-0x
Hardware Reference Guide
This document provides information about the system hardware components, mechanical, and
environmental specifications for the VSP N400 and VSP N600 storage systems.
MK-94HM8053-02
March 2021

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi VSP N400

  • Page 1 Hitachi Virtual Storage Platform N400, N600 83-06-0x Hardware Reference Guide This document provides information about the system hardware components, mechanical, and environmental specifications for the VSP N400 and VSP N600 storage systems. MK-94HM8053-02 March 2021...
  • Page 2 Hitachi, Ltd., or Hitachi Vantara LLC (collectively “Hitachi”). Licensee may make copies of the Materials provided that any such copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no other manner;...
  • Page 3: Table Of Contents

    Changes in this revision..................8 Document conventions..................8 Conventions for storage capacity values............10 Accessing product documentation..............11 Getting help......................11 Comments......................11 Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview....................12 Block configuration.....................12 Unified configuration..................13 VSP N400 model....................13 VSP N600 model....................16 Features......................19...
  • Page 4 Chapter 5: NAS module................56 NAS Module Ports and LEDs................56 Chapter 6: Maintaining the storage system..........58 Storing the storage system................58 Powering off the storage system................58 Battery unit......................59 Removing cables....................59 Contents VSP N400, N600 Hardware Reference Guide...
  • Page 5 Appendix A: Mechanical specifications for VSP N400, N600 ....61 VSP N400 and VSP N600 mechanical specifications........61 Appendix B: Electrical specifications for VSP N400, N600..... 70 Electrical specifications..................70 Appendix C: Environmental specifications for VSP N400, N600.... 72 Environmental specifications................72 Appendix D: iSCSI standards and specifications........
  • Page 6 Appendix I: Regulatory compliance............108 Appendix J: Environmental notices............110 Index....................111 Contents VSP N400, N600 Hardware Reference Guide...
  • Page 7: Preface

    Preface This guide describes the hardware features and specifications of the VSP N400 and VSP N600 storage systems. Intended audience This document is intended for Hitachi Vantara representatives, system administrators, authorized service providers, or customers who install, configure, and operate the VSP N400 and VSP N600 storage systems.
  • Page 8: Product Version

    Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document. Release notes are available on Hitachi Vantara Support Connect: https://knowledge.hitachivantara.com/Documents.
  • Page 9 Calls attention to important or additional information. Provides helpful information, guidelines, or suggestions for performing tasks more effectively. Caution Warns the user of adverse conditions and/or consequences (for example, disruptive operations, data loss, or a system crash). Preface VSP N400, N600 Hardware Reference Guide...
  • Page 10: Conventions For Storage Capacity Values

    1 KB 1,024 (2 ) bytes 1 MB 1,024 KB or 1,024 bytes 1 GB 1,024 MB or 1,024 bytes 1 TB 1,024 GB or 1,024 bytes 1 PB 1,024 TB or 1,024 bytes Preface VSP N400, N600 Hardware Reference Guide...
  • Page 11: Accessing Product Documentation

    Getting help Hitachi Vantara Support Website is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to the Hitachi Vantara Support Website for contact information: https://support.hitachivantara.com/en_us/contact- us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
  • Page 12: Chapter 1: Hitachi Virtual Storage Platform N400, N600 Hardware Overview

    Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview Hitachi Virtual Storage Platform N400, N600 are modular, rack-mountable, all-flash arrays that deliver high performance, high reliability, and flash-accelerated scalability. The storage system contain dual controllers, each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, fans and iSCSI and Fibre Channel I/O modules.
  • Page 13: Unified Configuration

    ■ VSP N400 model The VSP N400 is a highly reliable storage system that offers high storage capacity with full redundancy to better protect data and manage storage operations. The storage system consists of a 4U enclosure that includes two controllers and two NAS modules to support file operations.
  • Page 14 BNST) DW-F800- ■ DBLC (Silver-rated power supply) DW-F800- ■ DBLE (Platinum- rated power supply) FMD tray DW-F800- 5.25-inch FMD 2U (86.2 mm) ■ Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 15 2.4 TB DKC-F810I-6R0H9M LFF disk drive 6 TB DKC-F810I-10RH9M LFF disk drive 10 TB Flash module drives The VSP N400 storage system supports the listed flash module drive capacities. Model number Drive type Drive capacity DKC-F810I-7R0FP 7 TB DKC-F810I-14RFP 14 TB Solid-state drives The VSP N400 storage system supports the listed SSD capacities.
  • Page 16: Vsp N600 Model

    24 ports per systems when NAS Modules are installed) Controller Controller chassis Controller model Height CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm) Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 17 BNST) DW-F800- ■ DBLC (Silver-rated power supply) DW-F800- ■ DBLE (Platinum- rated power supply) FMD tray DW-F800- 5.25-inch FMD 2U (86.2 mm) ■ Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 18 Model number Drive type Drive capacity DKC-F810I-7R0FP 7 TB DKC-F810I-14RFP 14 TB Solid-state drives The VSP N600 storage system supports the listed SSD capacities. Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 19: Features

    1.9 TB DKC-F810I-3R8MGM 3.8 TB DKC-F810I-7R6MGM 7.6 TB Features The features described in the table are included with VSP N400 and VSP N600. Feature Value Maximum cache memory supported VSP N400:128 GB VSP N600: 256 GB Maximum number of spare drives...
  • Page 20: Scalability

    SFF drive tray 576 HDDs or SSDs LFF drive tray 288 HDDs or SSDs FMD tray 288 HAF flash module drives Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 21: Maximum Number Of Mounted Drive Trays

    Note: If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked. Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 22 SFF drive + LFF drive + VSP N400 SFF, LFF Dense intermix dense intermix dense intermix controller drives drive tray drive tray drive tray CBLM Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 23 SFF drive + LFF drive + VSP N600 SFF, LFF Dense intermix dense intermix dense intermix controller drives drive tray drive tray drive tray CBLM Chapter 1: Hitachi Virtual Storage Platform N400, N600 hardware overview VSP N400, N600 Hardware Reference Guide...
  • Page 24: Chapter 2: Virtual Storage Platform N400, N600 Controller

    Each controller includes the following internal components such as a processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator. If the data path through one controller fails, all drives remain available to data hosts using a redundant data path through the other controller.
  • Page 25: Cblm Front Panel Leds (Without Bezel)

    CBLM front panel LEDs (without bezel) The following table describes the definitions of the CBLM controller front panel LEDs. Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 26 Cache flash memory ALM LED (for cache flash Red: Cache flash memory memory) can be removed. CTL ALM LED Red: Controller can be removed. Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 27: Cblm Rear Panel

    (for example, BKMF-10 and BKMF-20). CBLM rear panel The following table describes the definitions of the CBLM controller rear panel LEDs. Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 28 CBLM rear panel Number Item Power supply unit Front end module Back end module LAN blade Rear view (includes NAS modules) Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 29: Cblm Power Supply Unit Leds And Connectors

    The controllers are equipped with specific interfaces for connecting, powering, configuring, and managing the storage system. The component LEDs display the operating status of the storage system. Front-end modules Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 30: 10-Gbps Iscsi Board Leds And Connectors (Optical)

    Blue: Normal link status at 16-Gbps. Green: Normal link status at 4-Gbps or 8-Gbps. Fibre Channel connectors Connect to Fibre Channel cables. Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 31 16-Gbps Fibre Channel ports (left to right) CHB number Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 32: Lan Blade Leds And Connectors

    LAN port used by the user. LAN 1 Maintenance LAN port used by service personnel. LAN ALARM LED Red: LAN blade can be removed. Uninterruptible power supply (UPS) port Back-end modules Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 33 Red: Back-end module can be removed safely. PORT LED Blue: Link status is normal. PATH 0 connector Connect to a drive tray. PATH 1 connector Connects to a drive tray. Chapter 2: Virtual Storage Platform N400, N600 controller VSP N400, N600 Hardware Reference Guide...
  • Page 34: Chapter 3: Drive Trays

    DBSE DW-F800-DBSE 2U (88.2 mm) 2.5 inch (SFF) SFF with front panel bezel Number Item Description POWER LED Green: Drive tray is powered READY LED Green: Drive tray is operational. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 35: Sff Front Panel Without Bezel

    Can be turned on or ■ turned off by the maintenance utility. ALM LED Red: Drive stopped due to a failure and can be replaced. ACT LED Green: Normal operation. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 36: Sff Rear Panel

    ALARM LED Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 37: Sff And Lff Ac Power Supply Unit Leds And Connectors

    The DBS and DBL power supply has a Silver efficiency rating. The DBSE and DBLE power supply has a Platinum efficiency rating. Number Item Description RDY LED Green: Normal operation. ACI IN LED Green: AC input is operating normally. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 38: Sff Power Supply Unit Leds And Connectors

    The following describes the physical specifications of the large form-factor drive tray. Number of Name Model name Height drive slots Drive type DW-F800-DBLC 2U (88.2 mm) 3.5 inch (LFF) DBLE DW-F800-DBLE 2U (88.2 mm) 3.5 inch (LFF) Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 39: Lff With Front Panel Bezel

    Locks and unlocks the front panel bezel by using the supplied key. LFF front panel without bezel Number Item Description POWER, READY, and Green: Drive tray is powered LOCATE LEDs Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 40: Lff Rear Panel

    The slots are organized in the following order: LFF rear panel Number Item Description POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 41: Sff And Lff Ac Power Supply Unit Leds And Connectors

    LEDs to display its operating status. Note: The DBS and DBL power supply has a Silver efficiency rating. The DBSE and DBLE power supply has a Platinum efficiency rating. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 42: Sff Power Supply Unit Leds And Connectors

    Green: DC input is operating normally. ALM LED Red: Power supply unit can be replaced. Flash module drive tray (DBF) The following describes the physical specifications of the flash module drive tray. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 43: Fmd With Front Panel Bezel

    Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 44: Fmd Front Panel Without Bezel

    Note: ACT indicator is only printed on some types of FMDs. POWER, READY, and Green: Drive tray is powered LOCATE LEDs Green: Drive tray is operational. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 45: Fmd Rear Panel

    Green: ENC is in the power- on state. Locate LED Amber: Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 46: High-Density Intermix Drive Tray (Db60)

    The following describes the physical specifications of the high-density drive tray. Number of Name Model name Height drive slots Drive type DB60 DW-F800- 4U (176 mm) 3.5 inch (LFF) DB60C Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 47: Dense Intermix Drive Tray With Front Panel Bezel

    Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 48: Dense Intermix Drive Tray Display Leds

    Rear of drive tray: 48-59 ■ 36-47 ■ 24-35 ■ 12-23 ■ Front of drive tray: 00-11 ■ Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 49: Dense Intermix Drive Tray Rear Panel

    PATH (IN) LED Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Console This port is reserved. ALARM LED Red: ENC can be replaced. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 50 Amber: Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays VSP N400, N600 Hardware Reference Guide...
  • Page 51: Chapter 4: Host Port Expansion Chassis

    Green: Host port expansion is turned on. Amber: PCIe module is turned on. Off: PCIe module is turned off. Safety lock Lock or unlock the front bezel. PCIe switchboard Chapter 4: Host port expansion chassis VSP N400, N600 Hardware Reference Guide...
  • Page 52: Host Port Expansion Chassis Fan

    Red: PCIe switchboard can be replaced safely. Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. Chapter 4: Host port expansion chassis VSP N400, N600 Hardware Reference Guide...
  • Page 53: Pcie Cable Connector

    InAct Basic LED Amber: Basic PCIe status changed from link up to link down and cables. Cables can be removed safely. Off: Basic PCIe is normal or not set. Chapter 4: Host port expansion chassis VSP N400, N600 Hardware Reference Guide...
  • Page 54: Host Port Expansion Chassis Power Supply

    Off: Option PCIe is normal or not set. Host port expansion chassis power supply Number Item Description ALM / RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. Chapter 4: Host port expansion chassis VSP N400, N600 Hardware Reference Guide...
  • Page 55 Host port expansion chassis power supply Number Item Description AC IN LED Blue: AC input is normal. Chapter 4: Host port expansion chassis VSP N400, N600 Hardware Reference Guide...
  • Page 56: Chapter 5: Nas Module

    The NAS module provides communication ports to support file system protocols in a block- or file-system configuration. NAS Module Ports and LEDs Legend Name Color Description User LAN port This is used with the file level access. Chapter 5: NAS module VSP N400, N600 Hardware Reference Guide...
  • Page 57 Cluster port Reserved for future Status LED Green NAS modules are functioning normally. NAS modules can be removed. Link LED Blue Displays link status. Fail LED A failure has occurred. Chapter 5: NAS module VSP N400, N600 Hardware Reference Guide...
  • Page 58: Chapter 6: Maintaining The Storage System

    3. Verify the POWER LED on the front of the storage system changes from green to amber. 4. To stop the power supply, remove the power cables from the power supply units on the controller chassis and drive box. Chapter 6: Maintaining the storage system VSP N400, N600 Hardware Reference Guide...
  • Page 59: Battery Unit

    Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Chapter 6: Maintaining the storage system VSP N400, N600 Hardware Reference Guide...
  • Page 60 SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Chapter 6: Maintaining the storage system VSP N400, N600 Hardware Reference Guide...
  • Page 61: Appendix A: Mechanical Specifications For Vsp N400, N600

    Appendix A: Mechanical specifications for VSP N400, N600 The storage system mechanical specifications are described for VSP N400, N600. VSP N400 and VSP N600 mechanical specifications Controller Quantity Component Description CBLM A 4U controller chassis consisting of controllers, channel boards, disk boards,...
  • Page 62 ENC and AC-DC power supplies equipped with built-in cooling fans. NAS module Component Description NAS module Component for block and file storage configuration Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 63 2305.58 GB: 10,000 RPM tray - DB60) 3916.14 GB: 7,200 RPM 5874.22 GB: 7,200 RPM 9790.36 GB: 7,200 RPM Only available for DB60/DB60C dense intermix drive tray. Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 64 NAS module 10-Gbps (Fibre Channel optical) Data transfer speed Fibre Channel optical 800-Mbps (Fibre Channel) (maximum speed for transfer 1600-Mbps (Fibre Channel) to host) 3200-Mbps (Fibre Channel) Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 65 8-Gbps Fibre Channel Module installed) optical 16-Gbps Fibre Channel optical (2-port) 16-Gbps Fibre Channel optical (4-port) 32-Gbps Fibre Channel optical (4-port) 10-Gbps optical iSCSI 10-Gbps copper iSCSI Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 66 3 TB (or 4 TB when using the LDEVs of other storage systems) Maximum volumes/host groups and iSCSI 2048 targets Maximum number of volumes per RAID 2048 group Shared memory and data assurance Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 67 19.01 x 30 x 3.42 inches (483 x 762 x 87 Dense intermix drive tray (DB60) 18.97 x 40.51 x 6.92 inches (482 x 1,029 x 176 mm) (includes the depth of the cable- management arms) Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 68 Cache specifications Item Specification Capacity (GB) VSP N400: 128 VSP N600: 256 NAS module Cache Capacity DDR3 DIMM 8GB x 12 [Slot] Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 69 3 hours every six months. Insulation performance Item Specification Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more Appendix A: Mechanical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 70: Appendix B: Electrical Specifications For Vsp N400, N600

    3460 or less Steady-state power (VA/W) CBLM: 1600/1560 or less SFF drive tray: 480/460 or less LFF drive tray: 380/350 or less FMD drive tray: 520/490 or less Appendix B: Electrical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 71 3. This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Appendix B: Electrical specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 72: Appendix C: Environmental Specifications For Vsp N400, N600

    (°C/h) State Controller FMD drive trays Operating 50°F to 104°F DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is (10°C to 40°C) installed: 50°F to 95°F (10°C to 35°C) Appendix C: Environmental specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 73 5.0 or less at 5 Hz to 300 Hz (no damage to product) 9.8 (1.0 G) Within 5 seconds (resonance point: 10 Hz or less) Transport (packed) 5.0 or less Appendix C: Environmental specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 74 3,000 (Environmental temperature: 10°C to 32°C) (Environmental temperature: 900 (Environmental temperature: 10°C to 40°C) when 10°C to 32°C) DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is installed. (Environmental temperature: 10°C to 40°C) Non-operating -60 to 12,000 Appendix C: Environmental specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 75 32°C or less) (Environment temperature 32°C or less) temperature 32°C or less) Non- 55 dB 55 dB 71 dB (Environmental operat temperature 32°C or less) Appendix C: Environmental specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 76 3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Appendix C: Environmental specifications for VSP N400, N600 VSP N400, N600 Hardware Reference Guide...
  • Page 77 Hitachi storage systems are designed and manufactured for reliable operation when placed 2 meters from the source of the noise. Hitachi does not test storage systems and hard disk drives for compatibility with fire suppression systems and pneumatic sirens. Hitachi also does not provide recommendations or claim compatibility with any fire suppression systems and pneumatic sirens.
  • Page 78: Appendix D: Iscsi Standards And Specifications

    RFC 1231 MIB II ■ RFC 1757 RMON ■ RFC 1901 SNMPv2 ■ iSCSI specifications Item Specification Comments iSCSI target function Supported ® iSCSI target function Supported TrueCopy only Appendix D: iSCSI standards and specifications VSP N400, N600 Hardware Reference Guide...
  • Page 79 Unique value. Cannot be changed. Maximum transfer unit 1,500, 4,500, 9,000 bytes Jumbo frame, MTU size (MTU) (Ethernet frame) greater than 1500 Link aggregation Not supported Tagged VLAN Supported IPv4 Supported Appendix D: iSCSI standards and specifications VSP N400, N600 Hardware Reference Guide...
  • Page 80 IPv6 router is connected to the same network, and then set IPv6 global address automatically. Subnet mask Supported Gateway address Supported DHCP Ping (ICMP ECHO) Supported Transmit, Receive IPsec Appendix D: iSCSI standards and specifications VSP N400, N600 Hardware Reference Guide...
  • Page 81 Maximum iSCSI connections 255 per iSCSI port at one time CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session. Appendix D: iSCSI standards and specifications VSP N400, N600 Hardware Reference Guide...
  • Page 82 Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar 4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef Appendix D: iSCSI standards and specifications VSP N400, N600 Hardware Reference Guide...
  • Page 83: Appendix E: Replacement Parts

    When replacing the battery, follow the given procedure for disposing a used battery. Replacement period The battery lifetime (intake temperature is 30 degrees C or less.) in the standard environment is as shown below. Appendix E: Replacement parts VSP N400, N600 Hardware Reference Guide...
  • Page 84: Appendix F: Data And Power Cables

    Serial-attached SCSI (SAS) cables are used to connect drive trays to controllers and other drive trays. Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 85 Fibre Channel cable length based on cable size and port speed. Cable size Speed Maximum cable length 9 micron 1 Gbps 1 km (3281 ft) 2 Gbps 2 km (6562 ft) 50 micron 2 Gbps 300 m Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 86: Fibre Channel Cables

    Note: Due to high-speed serial data transfer via Fibre Channel, use high-quality FC cables that comply with the Fibre Channel-PH standard. The following figure shows FC direct connection and FC connection through a switch. Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 87 16 Gbps 114.8 ft (35 m) 328.08 ft (100 410.1 ft (125 m) — 32 Gbps 65.62 ft (20 m) 229.7 ft (70 m) 328.08 ft (100 — Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 88 GC50, Wavelength: 125-2SR 850 nm (OMx) LC-LC cable DXLC-2PS- 9/125 μm (longwave) SPC-xxM- Singlemode Wavelength: 10/125-2SR 1300 nm The following figure shows the connector used for optical interfaces. Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 89: Iscsi Cables

    Interface name Cable One side Other side LC-LC cable Optical Equivalent to 50, 125 mm LC connector LC connector DXLC-2P- Multimode PC-xxM- Wavelength: GC50, 850 nm 125-2SR (OMx) Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 90 LC connector type ■ Connector type: LC duplex receptacle connector ■ Interval: 6.25 mm flat type, two rows ■ Cable specifications for 10 Gbps iSCSI copper interface Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 91: Iscsi Standards

    RFC 783 TFTP ■ RFC 791 IP ■ RFC 793 TCP ■ RFC 1157 SNMP v1 ■ RFC 1231 MIB II ■ RFC 1757 RMON ■ RFC 1901 SNMPv2 ■ Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 92: Iscsi Specifications

    Unique value. Cannot be changed. Maximum transfer unit 1,500, 4,500, 9,000 bytes Jumbo frame, MTU size (MTU) (Ethernet frame) greater than 1500 Link aggregation Not supported Tagged VLAN Supported IPv4 Supported Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 93 IPv6 router is connected to the same network, and then set IPv6 global address automatically. Subnet mask Supported Gateway address Supported DHCP Ping (ICMP ECHO) Supported Transmit, Receive IPsec Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 94 Maximum iSCSI connections 255 per iSCSI port at one time CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session. Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 95: Managing Cables

    Minimum bend radius values Fibre Channel 40 mm (1.73 inch) iSCSI optical 40 mm (1.73 inch) Category 5 Ethernet Four times the outside diameter of the cable 40 mm (1.73 inch) Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 96 When cabling full-width modules, such as NAS modules as shown in the following figure, route the cables horizontally, so that they do not interfere when replacing a module. Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 97: Ac Power Cables

    Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended. Appendix F: Data and power cables...
  • Page 98: Power Cable Assemblies

    Power cable assemblies Power cable assemblies For information about racks and power distribution units (PDUs), refer to the Hitachi Universal V2 Rack Reference Guide. Hitachi power cables consist of three parts: Plug: Male connector for insertion into the AC outlet providing power. The physical design ■...
  • Page 99: Ac Connections

    8. 5-wire (three-phase, earth and neutral). Physical variations (connector size and color) indicate amperage rating. AC connections The following table shows and describes the types of AC connections on your storage system. Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 100 3 IEC 83 CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 BS-1363 200V-240V 5 BS 1365 3 IEC 83 AS-3112 200V-240V 6 AS C112 Appendix F: Data and power cables VSP N400, N600 Hardware Reference Guide...
  • Page 101: Power Cable Usage Guidelines

    Cable and connector Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: Type of AC line feed provided by the facility.
  • Page 102: Three-Phase Power Considerations For Racks

    Cable management Rack installations should be planned for operational efficiency, ease of maintenance, and safety. Hitachi offers the Backend Configuration Utility (BECK), a graphical, cable- management application that can relieve the typical cable congestion created when populating a rack with storage systems and their accessories.
  • Page 103: Appendix G: Port Address Mapping

    The following addresses are available for setting Fibre Channel ports. Loop ID Loop ID Loop ID Loop ID Loop ID AL-PA (0~29) AL-PA (30~59 AL-PA (60~89) AL-PA (90~119) AL-PA (120~125) Appendix G: Port address mapping VSP N400, N600 Hardware Reference Guide...
  • Page 104 Port address mapping Loop ID Loop ID Loop ID Loop ID Loop ID AL-PA (0~29) AL-PA (30~59 AL-PA (60~89) AL-PA (90~119) AL-PA (120~125) Appendix G: Port address mapping VSP N400, N600 Hardware Reference Guide...
  • Page 105: Appendix H: Non-Hitachi Racks

    PDUs and cable loops. Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
  • Page 106: Hitachi Universal V2 Rack Accessories

    2. CGR: Corner guide rail kit A3BF-HK-GL-740-1. Hitachi Universal V2 Rack accessories The following table provides rack accessory information for VSP G series storage systems. Table 2 Accessories for the Hitachi Universal V2 Rack Front door Rear door Side panels...
  • Page 107 Third-party rack support for DB60 dense intermix drive trays Appendix H: Non-Hitachi racks VSP N400, N600 Hardware Reference Guide...
  • Page 108 Appendix I: Regulatory compliance This equipment has been tested and certified for compliance with the following standards. Appendix I: Regulatory compliance VSP N400, N600 Hardware Reference Guide...
  • Page 109 USA and Canada 60950-1:2007 EN60950-1:2006+A1 TUV Germany IEC60950-1:2005+A All CB countries IEC60950-1:2005+A S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan EN60950-1:2006+A1 CE Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Appendix I: Regulatory compliance VSP N400, N600 Hardware Reference Guide...
  • Page 110 They will dispose of it for you. This nickel-metal hydride battery, which is designated as recycling product by a recycling promotion low, must be recycled. The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part. Appendix J: Environmental notices VSP N400, N600 Hardware Reference Guide...
  • Page 111 LEDs power supply cables drive trays AC power dense intermix Fibre Channel flash module iSCSI large form-factor managing maximum number removing small form-factor required CBLH controller rear panel Index VSP N400, N600 Hardware Reference Guide...
  • Page 112 LEDs PCIe switchboard power supply Port address mapping ports interconnect adapter power cable assemblies Fibre Channel power cables iSCSI PCIe board power off iSCSI power on cable removal power supply unit Index VSP N400, N600 Hardware Reference Guide...
  • Page 113 78, mechanical standards standards for iSCSI 78, storage storage system maintenance power off regulatory compliance storing storage system controllers CBLM storage system specifications Index VSP N400, N600 Hardware Reference Guide...
  • Page 114 Hitachi Vantara Corporate Headquarters Contact Information 2535 Augustine Drive USA: 1-800-446-0744 Santa Clara, CA 95054 USA Global: 1-858-547-4526 HitachiVantara.com | community.HitachiVantara.com HitachiVantara.com/contact...

This manual is also suitable for:

Vsp n600

Table of Contents