Hitachi Virtual Storage Platform G130 Hardware Reference Manual

Hitachi Virtual Storage Platform G130 Hardware Reference Manual

Hide thumbs Also See for Virtual Storage Platform G130:

Advertisement

Hitachi Virtual Storage Platform G130
88-02-0x
Hardware Reference Guide
This document provides information about the system hardware components and the mechanical and
environmental specifications for the Hitachi Virtual Storage Platform G130 storage system.
MK-97G130004-00
September 2018

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi Virtual Storage Platform G130

  • Page 1 Hitachi Virtual Storage Platform G130 88-02-0x Hardware Reference Guide This document provides information about the system hardware components and the mechanical and environmental specifications for the Hitachi Virtual Storage Platform G130 storage system. MK-97G130004-00 September 2018...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    Chapter 3: Parts list................48 Components list....................48 Data and power cable model list................51 Chapter 4: Operational and maintenance considerations....55 Network access....................55 TCP/IP port assignments................55 Controller connections..................58 Physical service processor connections............58 Contents Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 4 Powering off the storage system................59 Storing the storage system................60 Appendix A: Environmental notices........... 61 Appendix B: Regulatory compliance..........62 Contents Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 5: Preface

    This guide describes the hardware features and specifications of the VSP G130 storage system. Intended audience This document is intended for Hitachi Vantara representatives, system administrators, and authorized service providers who install, configure, and operate the VSP G130 storage system.
  • Page 6: Product Version

    Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document. Release notes are available on Hitachi Vantara Support Connect: https://knowledge.hitachivantara.com/Documents.
  • Page 7: Conventions For Storage Capacity Values

    Warns the user of a hazardous situation which, if not avoided, could result in death or serious injury. Conventions for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 8: Accessing Product Documentation

    1 EB 1,024 PB or 1,024 bytes Accessing product documentation Product user documentation is available on Hitachi Vantara Support Connect: https:// knowledge.hitachivantara.com/Documents. Check this site for the most current documentation, including important updates that may have been made after the release of the product.
  • Page 9: Getting Help

    Getting help Getting help Hitachi Vantara Support Connect is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to Hitachi Vantara Support Connect for contact information: https://support.hitachivantara.com/en_us/ contact-us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
  • Page 10: Chapter 1: Overview

    Optional service processor (SVP) ■ System configurations The following table lists the supported system configurations with maximum mountable drive tray and data drives for the VSP G130 storage system. Chapter 1: Overview Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 11 System configurations Number of mountable drive trays Controller Maximum number of mountable SAS chassis Drive tray Maximum drives CBSS CBSL Chapter 1: Overview Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 12: Chapter 2: Hardware Components And Specifications

    32 GiB Cache flash memory capacity BM05 Storage Controller/drive chassis interface SAS/Dual Port interface Data transfer rate Maximum 12 Gb/s Maximum number of drives per SAS interface Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 13 Device installation position: The Controller Chassis is at the bottom of the rack ■ and the Drive Box is at a height of 1.5m in the rack. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 14 ■ and right). 3. It is recommended to install the Hitachi Vantara storage system into a data center. However, you can install the storage system into an office space but the space should be equipped with proper cooling systems and noise insulation. When you...
  • Page 15 Note: The VSP G130 storage system components are not supported in high- temperature environments. Do not operate the Hitachi Vantara-provided service processor (SVP) at temperatures of 40°C or higher. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 16 80 or less (m/s Storage system tips over at 15° or less 15° or less To be measured specific angle (°) when installed on leveling bolts. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 17 The recommended acoustic noise level for an operating environment is 90dB or less in order to ensure reliable operations when placing a Hitachi Vantara storage system two meters from the source of the noise. Chapter 2: Hardware components and specifications...
  • Page 18 The customer is responsible to follow their local or national regulations. To prevent I/O error or damages to HDDs in the storage systems, Hitachi Vantara recommends the following: Install noise-reducing baffles to mitigate the noise to the HDDs in the storage ■...
  • Page 19: Vsp G130 Controller Chassis

    ■ and right) 7. It is recommended to install the Hitachi Vantara storage system into a data center. However, you can install the storage system into an office space but the space should be equipped with proper cooling systems and noise insulation. When you...
  • Page 20 With a maximum configuration 1 controller chassis and 3 drive trays, start-up time is approximately 8 minutes. 2. Can be mounted on the Hitachi Universal V2 rack. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 21 4 years Up to 104º (40º C) 3 years CBSS component LEDs The following table lists the definitions of the CBSS controller chassis front panel bezel LEDs. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 22 The following table describes the definitions of the CBSS controller front panel LEDs without an attached front bezel. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 23 The slots are arranged from left to right drive slots and organized as 0 to 23. The following table describes the definitions of the CBSS controller real panel LEDs. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 24 Controller chassis with small form-factor drive bays (CBSS) Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 25 Link to port is established. Controller Controller can be removed. (CLT) ALM Blink Failure occurred to controller power supply. Amber LAN switched is pressed. SAS port SAS cable port. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 26: Controller Chassis With Large Form-Factor Drive Bays (Cbsl)

    The following describes the CBSL controller chassis technical specifications and associated physical features of the controller. CBSL mechanical specifications The following table provides a description and specifications of the CBSL controller chassis. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 27 With a maximum configuration 1 controller chassis and 7 drive trays, start-up time is approximately 8 minutes. 2. Can be mounted on the Hitachi Universal V2 rack. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 28 3 years Up to 104º (40º C) 2 years CBSL component LEDs The following table describes the definitions of the CBSL controller front panel bezel LEDs. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 29 The following table describes the definitions of the CBSL controller front panel LEDs without an attached front bezel. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 30 The slots are organized from 0 to 11 in the drive slots following order: The following table describes the definitions of the CBSL controller real panel LEDs. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 31 Controller chassis with large form-factor drive bays (CBSL) Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 32 Link to port is established. Controller Controller can be removed. (CLT) ALM Blink Failure occurred to controller power supply. Amber LAN switched is pressed. SAS port SAS cable port. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 33: Drive Trays

    The following tables provide information about the DBS drive tray specifications and supported configurations for VSP G130 storage system. Number of Supported Name Model number Height drive slots drive type DW-F800-DBSC 2U (88.2 mm) 2.5 inch (SFF) Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 34 With a maximum configuration 1 controller chassis and 3 drive trays, start-up time is approximately 8 minutes. 2. Can be mounted on the Hitachi Universal V2 rack. For the mounting, special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems.
  • Page 35 Indicates the location of the chassis. Can be turned on or turned off by the maintenance utility. Lock Locks or unlocks the front panel bezel by using the supplied key. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 36 The slots are arranged from left to right and organized as 0 to 23. The following table lists the definitions of the DBS drive tray rear panel components and LEDs. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 37 Small form-factor drive tray (DBS) Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 38 Drive tray is under normal operation. ALM LED Red Power supply unit stopped due to a failure and can be replaced. RDY LED Green Power supply unit is under normal operation. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 39: Large Form-Factor Drive Tray (Dbl)

    With a maximum configuration 1 controller chassis and 7 drive trays, start-up time is approximately 8 minutes. 2. Can be mounted on the Hitachi Universal V2 rack. For the mounting, special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems.
  • Page 40 Indicates the location of the chassis. Can be turned on or turned off by the maintenance utility. Lock Locks or unlocks the front panel bezel by using the supplied key. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 41 The slots are organized in the following order: The following table lists the definitions of the DBL drive tray rear panel components and LEDs. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 42 Large form-factor drive tray (DBL) Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 43 Drive tray is under normal operation. ALM LED Red Power supply unit stopped due to a failure and can be replaced. RDY LED Green Power supply unit is under normal operation. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 44: Service Processor

    ■ Turning on automatic Windows updates or using the manual Windows update ■ method. Installing antivirus software that has been tested and approved by Hitachi. ■ Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 45: Svp Front Panel

    SVP front panel The front panel of the physical SVP with Windows 10 Enterprise operating system is equipped with LEDs, a reset button, and a power button. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 46: Svp Rear Panel

    Table 3 SVP (Windows 10 Enterprise) rear panel Item Description Management (DKC CTL1) - LAN3 port Management (DKC CTL2) - LAN4 port Maintenance - LAN2 port Management (User) - LAN1 port Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 47 In this mode, the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches. For more information, contact customer support. Chapter 2: Hardware components and specifications Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 48: Chapter 3: Parts List

    600 GB, 2.5-inch, 10kmin, 0-24 12 Gbps, SAS drive DKC-F810I-1R2JCMC 1.2 TB, 2.5-inch, 10kmin, 12 0-24 Gbps, SAS drive DKC-F810I-2R4JGM 2.4 TB, 2.5-inch, 10kmin, 12 0-24 Gbps, SAS, drive Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 49 Part description Quantity DW-F850-CTLXSFA Controller board (FC 16- Gbps) DKC-F810I-6R0H9M 6 TB, 3.5-inch, 7.2kmin, 12 0-12 Gbps SAS drive DKC-F810I-10RH9M 10 TB, 3.5-inch, 7.2kmin, 12 0-12 Gbps SAS drive Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 50 600 GB, 2.5-inch, 10kmin, 0-24 12 Gbps, SAS drive DKC-F810I-1R2JCMC 1.2 TB, 2.5-inch, 10kmin, 12 0-24 Gbps, SAS drive DKC-F810I-2R4JGM 2.4 TB, 2.5-inch, 10kmin, 12 0-24 Gbps, SAS, drive Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 51: Data And Power Cable Model List

    Quantity HDW2-F850-SVP.P Service processor (Windows 10 IoT Enterprise) Data and power cable model list The following tables list the data and power cables available to the storage system. Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 52 3 m SAS cable, including omega clips (2) DW-F800-SCQ5 5 m SAS cable, including omega clips (2) DW-F800-SCQ10A 10 m SAS optical cable DW-F800-SCQ30A 30 m SAS optical cable DW-F800-SCQ1HA 100 m SAS optical cable Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 53 30 m LC-LC optical cable for optical A-6515-JM50L 50 m LC-LC optical cable for optical A-6515-JM100L 100 m LC-LC optical cable for optical A-6515-JM200L 200 m LC-LC optical cable for optical Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 54 Data and power cable model list Model number Specification A-6515-JM300L 300 m LC-LC optical cable for optical Chapter 3: Parts list Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 55: Chapter 4: Operational And Maintenance Considerations

    Review the following ports before you install the storage system to avoid conflicts between the TCP/IP port assignments used by the storage system and those used by other devices and applications. Chapter 4: Operational and maintenance considerations Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 56 TCP/IP port assignments Port number Usage description Used by the SVP, Hitachi Storage Advisor, and Device Manager - Storage Navigatorto communicate through the HTTP protocol. UDP (SNMP uses this port to send traps from the storage system) . Used by SMI-S.
  • Page 57 S is not used. or later Automatic 88-02-0x -xx/00 allocation or later CommonJettySt HTTP 8080 88-02-0x -xx/00 or later CommonJettySt HTTP 8210 RestAPIServerS HTTP 9210 DeviceJettyStart HTTP 8081 Chapter 4: Operational and maintenance considerations Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 58: Controller Connections

    ■ Physical service processor connections The SVP is available as an optional, physical device provided by Hitachi Vantara or as a virtual guest host running on customer-provided ESX servers and VM/OS licenses and media. The SVP provides error detection and reporting and supports diagnostic and maintenance activities involving the storage system.
  • Page 59: Powering Off The Storage System

    The POWER LED is solid green during the powering off process. The POWER LED changes from green to amber when the process is completed. Chapter 4: Operational and maintenance considerations Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 60: Storing The Storage System

    Note: Do not store the equipment in an environment with temperatures of 104ºF (40ºC) or higher because battery life will be shortened. Chapter 4: Operational and maintenance considerations Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 61: Appendix A: Environmental Notices

    They will dispose of it for you. This nickel-metal hydride battery, which is designated as recycling product by a recycling promotion low, must be recycled. The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part. Appendix A: Environmental notices Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 62: Appendix B: Regulatory Compliance

    Appendix B: Regulatory compliance This equipment has been tested and certified for compliance with the following standards. Appendix B: Regulatory compliance Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 63 All CB countries 1+A2 IEC60950-1:2005+A S_Mark Argentina 1+A2 TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan EN60950-1:2006+A1 CE marking 1+A1+A12+A2 Radio interference VCCI V-3/2015.4 VCCI Japan voluntary control Appendix B: Regulatory compliance Hitachi Virtual Storage Platform G130 Hardware Reference Guide...
  • Page 64 This is a class A product. In a domestic environment this product can cause radio interference in which case the user can be required to take adequate measures. Appendix B: Regulatory compliance Hitachi Virtual Storage Platform G130 Hardware Reference Guide...