Environmental specifications

See
"Environmental specifications"
The following table defines the system level operating and non-operating
environmental limits for the NetBackup appliance and the Symantec Storage Shelf.
System Environmental Specifications
Table A-2
Parameter
State
Temperature
Non-operating
Operating
Humidity
Non-operating
Shock
Operating
Packaged
Unpackaged
Vibration
Unpackaged
Acoustic noise
Electrostatic
discharge (ESD)
System Cooling
Requirement
See
"750W single power supply input voltages"
Environmental specifications
on page 61.
Details
-40°F to 70°F
The maximum rate of change is 10°C to 35°C and
should not to exceed 10°C per hour.
90% relative humidity (non-condensing) at 28°C.
2.0-g peak , 11 msec, half sine
Non-palletized free fall in height 24" ( > 40 lbs to < 80
lbs)
Operational after an 18" free fall.
Trapezoidal, 25 g, velocity change 136 inches per sec.
5 Hz to 500 Hz, 2.20 g RMS random
Sound Power: 7.0 DBA in an idle state at typical office
ambient temperature (23 +/- 2°C)
+/-12 KV except I/O port +/- 8 KV
NetBackup appliance: 2550 BTU/Hr
Storage Shelf: 1270 BTU/Hr
on page 60.