Figure 168. SFP transceiver
5. Reconnect the Fibre Channel cable.
6. Confirm that the error is now fixed. Check the Fibre Channel port status using the front-panel display.
If possible, check the status given by the SAN monitoring tools of the customer. Either mark the error
as fixed or restart the node depending on the failure indication that you originally noted.

Removing the Fibre Channel adapter assembly

Use the information in this topic when you need to remove a Fibre Channel adapter or Fibre Channel
adapter assemblies.
Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a
static-protected mat or surface. For more information, see "Handling static-sensitive devices" on page xx.
Removing the SAN Volume Controller 2145-CG8 or 2145-CF8 Fibre Channel
adapter assembly
To remove the SAN Volume Controller 2145-CG8 or 2145-CF8 Fibre Channel adapter assembly, perform
|
the following steps:
DANGER
|
Multiple power cords. The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords. (L003)
|
| |
| |
| |