Parts Assembly - IBM SAN Volume Controller 2145-CG8 Hardware Maintenance Manual

System storage san volume controller series
Hide thumbs Also See for SAN Volume Controller 2145-CG8:
Table of Contents

Advertisement

v Table 6 calls out the FRUs that are referred to in service procedures.
v Table 7 on page 9 lists the FRUs that are not referred to by any SAN Volume Controller 2145-CF8
service procedure, but that might be replaced in some circumstances.
v Table 8 on page 9 lists the FRUs that are related to the optional solid-state drive (SSD) features.
Table 6. FRUs in the SAN Volume Controller 2145-CF8 parts assembly
Assembly
index
Part number
-1
44T1493
-2
31P1340
-3
33F8354
-4
31P1337
-5
39Y7201
-6
44E4372
-7
42D0673
-8
44T2248
-9
31P1339
-10
43V7071
-11
43V6929
Units
Description
6
Memory module
4 GB memory module, DDR3-1333 2RX4 LP RDIMM
1
Optional: High speed SAS adapter
An assembly that includes a high speed SAS adapter card that
provides connectivity for up to four solid-state drives (SSDs), a
riser card, a blanking plate, and screws.
1
CMOS battery
3.0 volt battery on the system board that maintains power to back
up system BIOS settings.
1
4-port Fibre Channel adapter
A Fibre Channel host bus adapter (HBA) assembly that connects
the SVC CF8 to the Fibre Channel fabric. It is located in PCI slot
1. The adapter assembly includes the Fibre Channel PCI Express
adapter, four short-wave small form-factor pluggable (SFP)
transceivers, the riser card, and the bracket.
Note: If the system is using alternative Fibre Channel SFP
transceivers, replace the SFP transceivers on the FRU part with
the SFP transceivers from the Fibre Channel adapter that is being
replaced.
2
Power supply unit
Ac power supply, 675 Watt
1
Operator-information panel
This assembly includes the information panel that contains the
power-control button and diagnostics LEDs.
1
Disk drive
The serial-attached SCSI (SAS) 2.5 inch disk drive, which, when
ordered as a replacement, might be a supported compatible drive
of at least the same capacity as the one being replaced.
4
Drive bay blank EMC filler assembly
1
Service controller
The service controller includes the front-panel display, buttons,
and associated electronics.
1
Disk backplane
Hot-swap SAS 2.5" disk-drive backplane
6
Fan assembly
The fan assembly is used in each of the six fan positions.
7
Chapter 1. Parts listing

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents