DANGER
v Do not install a unit in a rack where the internal rack ambient temperatures will exceed the
manufacturer's recommended ambient temperature for all your rack-mounted devices.
v Do not install a unit in a rack where the air flow is compromised. Ensure that air flow is not
blocked or reduced on any side, front, or back of a unit used for air flow through the unit.
v Consideration should be given to the connection of the equipment to the supply circuit so that
overloading of the circuits does not compromise the supply wiring or overcurrent protection. To
provide the correct power connection to a rack, refer to the rating labels located on the
equipment in the rack to determine the total power requirement of the supply circuit.
v (For sliding drawers) Do not pull out or install any drawer or feature if the rack stabilizer
brackets are not attached to the rack. Do not pull out more than one drawer at a time. The rack
might become unstable if you pull out more than one drawer at a time.
v (For fixed drawers) This drawer is a fixed drawer and must not be moved for servicing unless
specified by the manufacturer. Attempting to move the drawer partially or completely out of the
rack might cause the rack to become unstable or cause the drawer to fall out of the rack.
(R001 part 2 of 2)
To remove the SAN Volume Controller 2145-8G4 from a rack, complete these steps:
1. Remove the cable-retention bracket and disconnect the power cable from the node. See "Removing the
cable-retention bracket" on page 34.
2. To make sure that you can replace all cables in the same ports from which they were removed, record
the position of all Fibre Channel and Ethernet cables; then remove all cables from the back of the
node.
3. Slide the SAN Volume Controller 2145-8G4 node forward until it latches in the service position.
4. Position yourself to support the weight of the node when it is no longer held by the slides and then
press the rear slide release latches (
2145-8G4 node.
5. Pull the node forward and remove it from the rack.
1
Figure 35. Removing the SAN Volume Controller 2145-8G4 from the rack
Removing the SAN Volume Controller 2145-8F4 or SAN Volume Controller
2145-8F2 from a rack
Use these instructions when you are directed to remove a SAN Volume Controller 2145-8F4 or SAN
Volume Controller 2145-8F2 from a rack.
1
in Figure 35) on both sides of the SAN Volume Controller
2
Chapter 2. Removing and replacing parts
53