High-Speed Sas Cable In The San Volume Controller 2145-Cg8 Or 2145-Cf8 - IBM SAN Volume Controller 2145-CG8 Hardware Maintenance Manual

System storage san volume controller series
Hide thumbs Also See for SAN Volume Controller 2145-CG8:
Table of Contents

Advertisement

1
|
Figure 201. High-speed SAS adapter assembly and high-speed SAS cable in the SAN Volume Controller 2145-CG8 or
|
2145-CF8
1 High-speed SAS cable plugged into the high-speed SAS adapter assembly
2 High-speed SAS adapter assembly
2. Attach the high-speed SAS cable to the high-speed SAS adapter.
Attach the cable so that the end with the label is to the front of the node and the end without the
label attaches to the adapter.
3. Replace the high-speed SAS adapter card, as described in "Replacing the SAN Volume Controller
|
|
2145-CG8 or 2145-CF8 high-speed SAS adapter assembly" on page 198.
4. Disconnect the boot-disk SAS cable from the disk controller and move it out of the blue bulkhead clip.
5. Route the cable from the high-speed SAS adapter through the blue bulkhead clip behind the drive
backplane.
6. Attach the high-speed SAS cable to the SAS connector in the center of the back of the SAS drive back
plane. Use the connector that connects to drive bays 0, 1, 2, and 3.
The high-speed SAS cable is shown in Figure 202 on page 206.
|