Installing The Microprocessor - IBM SAN Volume Controller 2145-CG8 Hardware Maintenance Manual

System storage san volume controller series
Hide thumbs Also See for SAN Volume Controller 2145-CG8:
Table of Contents

Advertisement

5
Figure 296. Installing the microprocessor
1
Microprocessor orientation indicator
2
Microprocessor
3
Microprocessor orientation indicator
4
Microprocessor connector
5
Microprocessor release lever
6. Install a heat sink. If this is an original version of the SAN Volume Controller 2145-8G4 node, you
will install the other heat sink in step 7 on page 297.
a. Apply thermal grease to the top of the microprocessor. Apply nine dots of thermal grease in three
rows of three dots each with the outer rows approximately 5 mm from the edge of the
microprocessor. The diameter of the cap from the thermal grease syringe is 5 mm, so you can use
it to judge the required position of the dots of thermal grease, as shown in Figure 297 on page
297.
296
IBM SAN Volume Controller Hardware Maintenance Guide
1
2
3
4

Hide quick links: