Power Led On The San Volume Controller - IBM SAN Volume Controller 2145-CG8 Hardware Maintenance Manual

System storage san volume controller series
Hide thumbs Also See for SAN Volume Controller 2145-CG8:
Table of Contents

Advertisement

The power-cable assembly is composed of a power cable (two power cables in the SAN Volume
|
|
Controller model 2145-CG8 or model 2145-CF8) and a signal cable that are bound together. You can
remove the power-cable assembly if you have problems with the power supply and suspect that a power
|
or signal cable is defective. When removing the power-cable assembly, ensure that you also remove it
|
|
from the uninterruptible power supply.
Perform the following steps to remove the power-cable assembly:
|
1. Check the SAN Volume Controller models 2145-CG8, 2145-CF8, 2145-8A4, 2145-8G4, and 2145-8F4 or
2145-8F2 power LED ( 1 in Figure 90).
|
v If the light is on, go to step 2.
|
v If the light is either off or flashing, power has already been removed from the SAN Volume
|
|
Controller. Go to step 7 on page 104.
|
|
1
2145-CG8
2145-CF8
|
|
Figure 90. Power LED on the SAN Volume Controller models 2145-CG8, 2145-CF8, 2145-8A4, 2145-8G4, and
|
2145-8F4 or 2145-8F2 operator-information panel
1 Power LED
|
Important: SAN Volume Controller nodes operate in pairs. Both SAN Volume Controller nodes are
|
in the same I/O group. One SAN Volume Controller must be operational if you are servicing the
|
|
other SAN Volume Controller. If both SAN Volume Controller nodes are not functioning, you cannot
access any of the disks in that I/O group.
|
2. Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350 in the
IBM System Storage SAN Volume Controller Troubleshooting Guide for more information.
Attention: If both SAN Volume Controller nodes are online, removing the power from one SAN
Volume Controller can cause performance degradation while I/O operations are automatically
rerouted to other SAN Volume Controller. Ensure that this performance outcome is acceptable before
|
|
continuing with this procedure.
3. Press and release the power-control button 1 shown in Figure 91 on page 104 for SAN Volume
|
Controller models 2145-CG8, 2145-CF8, 2145-8A4, 2145-8G4, and 2145-8F4 or 2145-8F2. Wait one
|
|
minute for the SAN Volume Controller to turn off. Ignore a missing node error code if displayed by
other nodes in the cluster. When maintenance procedures are completed, the error will resolve itself.
|
|
1
2145-8A4
2145-8G4
1
1
2145-8F4
2145-8F2
Chapter 2. Removing and replacing parts
103