Register - Tele Radio TG-T14-4 Installation Instructions Manual

Tiger g2 industrial radio remote controls
Table of Contents

Advertisement

Logout from menu mode
 
1. Make sure that the stop button is pressed.
 
2. Twist and pull out the stop button.
The top LED lights (green when the battery capacity is good, red when the battery capacity is poor).
 
3. Press the right start button. Keep pressed.
 
4. Press the stop button.
 
5. Release the right start button.
The top LED flashes (green when the battery capacity is good, red when the battery capacity is poor)
when in menu mode.
 
6. Go to [Logout].
 
7. Select by pressing the left start button.
 
8. Select a receiver to log out from.
 
9. Confirm by pressing the left start button.
The display shows [Logging out...] while the process is ongoing.
If logout fails, the display shows [FAILED]. The transmitter turns off.
If logout succeeds, the display shows [OK]. The transmitter turns off after logging out.
 
 
 

REGISTER

 
WARNING! Do not perform this when the receiver is in a session with another transmitter. The radio
communication may become disturbed or broken.
 
NOTE! Before starting to perform these settings, make sure that the stop relays are deactivated!
 
Register the transmitter in the receiver
 
1. Press the receiver Function button.
Function LED 1 flashes red.
 
2. Relay LEDs 1-7 light to show how many transmitters that are already registered in the receiver.
 
3. Press the receiver Select button until all relay LEDs light red.
The receiver will stay in registering mode for 1 minute or until a transmitter has been registered.
 
4. On the transmitter: Make sure that the stop button is pressed.
 
5. Twist and pull out the stop button.
The top LED lights (green when the battery capacity is good, red when the battery capacity is poor).
 
6. Press the right start button. Keep pressed.
 
7. Press the stop button.
 
8. Release the right start button.
- 36 -

Hide quick links:

Advertisement

Table of Contents
loading