Amp - Dukane i220 User Manual

Iq series ultrasonic integrated press system
Hide thumbs Also See for i220:
Table of Contents

Advertisement

iQ Series
Ultrasonic Integrated Press System i 220 User's Manual
For all menus - When a button is pressed to access the menu, the last param-
eter accessed will be selected and ready to change if applicable.
Example: If the PRE WELD button is pressed, and the Trigger Distance value
was the setting last accessed in that menu, then Trigger Distance is selected
and ready to change.
On screen Prompts - Watch for and follow on screen prompts where they appear.
Example: In Figure 5-4 below the prompts are:
PRESS ENTER TO ACCEPT, or PRESS CANCEL TO ABORT

AMP

The menu in Figure 5-4 is the default display showing
WELD with its amplitude value highlighted, and ready
to be changed. This is true for either operating MODE: -
Automated Press or Manual Press.
This is the only available menu IF:
• Trigger is either Momentary or Maintained,
• Pre-trigger is disabled, and
• Postweld characteristics are disabled.
If AFTERBURST is enabled in the POST WELD menu,
then the AFTERBURST soft key is also displayed as
shown in Figure 5-5 to the right. The parameter value last
accessed will be highlighted and ready to change.
Page 52
Continued from Previous Page
NOTE
NOTE
Figure 5-4
Figure 5-5
AMPLITUDE
WELD
PRE  
POST  
AMP  
WELD  
WELD  
WELD  
Setting Weld Amplitude
AMPLITUDE
WELD
AFTERBURST
PRE  
POST  
AMP  
WELD  
WELD  
WELD  
Setting Weld Amplitude with Afterburst
Enabled
Dukane Manual Part No. 403-594-02
ONLINE      
100%
PRESS ENTER TO ACCEPT
PRESS CANCEL TO ABORT
LIMITS  
SETUPS  
LIVE  
SETUP
OPERATE  
ONLINE      
100%
PRESS ENTER TO ACCEPT
PRESS CANCEL TO ABORT
LIMITS  
SETUPS  
OPERATE  
LIVE  
SETUP
Continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents