Automation System - Dukane i220 User Manual

Iq series ultrasonic integrated press system
Hide thumbs Also See for i220:
Table of Contents

Advertisement

Automation System

User-supplied automation equipment connects to the press
System I/O Panel through:
J1, a 25-pin connector, and
J6, a 9-pin connector.
J1 - User-supplied external controls provide the press with
input/output signals that direct operation of the press.
Table 3-I - System Input/Output Connector Signals
the 25-pin connector's input and output signal names.
See Pages 21-23 for signal descriptions.
J6 - Attach the finished end (9-pin female connector) of
Dukane cable Part Number 200-1546-xxM
Press System I/O Panel. With the open end of the cable the
user can make connections from user-supplied equipment
to provide for the functions the Dukane cable typically has.
See the table below.
Pin No.
Type
1
Input
2
Input
3
Input
4
Input
5
Ground
6
Input
7
+22VDC
8
Input
9
+22VDC
Table 3-III
Dukane Cable 200-1546-00 Signals
**
xxM = A value representing cable length in Meters.
This number is typically determined when ordering the equipment.
Dukane Manual Part No. 403-594-02
**
to J6 on the
Function
Activation Switch 1 N.O.
Activation Switch 2 N.O.
Hardware Abort Power In
Software Abort
Internal Ground
Activation Switch 1 N.C.
Switch Power Out
Activation Switch 2 N.C.
Hardware Abort Power Out
shows
-
Normally Open (N.O.) dry contact closure to Pin 7
Normally Open (N.O.) dry contact closure to Pin 7
Normally Closed (N.C.) emergency switch contact
Normally Open (N.O.) dry contact closure to ground
Internal Ground (Gnd)
Normally Closed (N.C.) dry contact closure to Pin 7
Power for switches when abort inactive.
Normally Closed (N.C.) dry contact closure to Pin 7
Normally Closed (N.C.) emergency switch contact