Pin
Signal Name
1
Solenoid Output
2
In Cycle Status Output
3
Front Panel Lockout Input
4
READ RELAY NO Output
5
READY RELAY Common
6
Not Used
7
Not Used
8
+22VDC Power Supply
9
+22VDC Power Supply
10
Bad Part Status Output
11
Top of Stroke Status Output
12
Not Used
13
Hold Status Output
14
System latch Reset
15
Input Common
16
+22VDC Power Ground
17
+22VDC Power Ground
18
+22VDC Power Ground
19
Ultrasound Active Status
20
System Ready Status
21
Any Fault Status
22
Output Common
23
Output Common
24
U/S Activate Common
25
U/S Activate/Cycle Start
Input
Table 3-I
System Input/Output Connector Signals (J1)
Dukane Manual Part No. 403-594-02
Continued from Previous Page
Cable Color
Code
BLK
Non-isolated active low digital output that is active from start of a cycle
to end of Hold (referenced to chassis ground).
WHT
Isolated output referenced to Output Common that is active from start
of a cycle to end of Hold.
RED
Isolated input refrenced to Input Common that locks the front panel
user interface.
GRN
Isolated output that is referenced to READY RELAY Common that is
active when the press is ready to start a cycle.
ORN
Common for READY RELAY NO Output
BLU
WHT/BLK
RED/BLK
+22VDC for customer automation controls. Limited to 500mA total for
both pins.
GRN/BLK
+22VDC for customer automation controls. Limited to 500mA total for
both pins.
ORN/BLK
Isolated output referenced to Output Common that activates when bad
part limit(s) are exceeded.
BLU/BLK
Isolated input referenced to Input Common that resets the Any Fault or
System Overload status outputs.
BLK/WHT
RED/WHT
Isolated output referenced to Output Common that indicates when in
the Hold part of a weld cycle.
GRN/WHT
Isolated input referenced to Input Common that resets the Any Fault or
System Overload status outputs.
BLU/WHT
Isolated input Common
BLK/RED
+22VDC Power Ground (also chassis ground)
WHT/RED
+22VDC Power Ground (also chassis ground)
ORN/RED
+22VDC Power Ground (also chassis ground)
BLU/RED
Isolated output referenced to Output Common that indicates ultrasound
is being output.
RED/GRN
Isolated output referenced to Output Common that is active when the
press is ready to start a cycle.
ORN/GRN
Isolated output referenced to Output Common that is active when the
any fault/alarm is detected.
BLK/WHT/RED Isolated Output Common.
WHT/BLK/RED Isolated Output Common.
RED/BLK/WHT Isolated U/S Activate/Cycle Start.
GRN/BLK/WHT Isolated input referenced to Isolated U/S Activate/Cycle Start Input
Common that starts a cycle when activated.
Section 3 - Installation