System Operating Mode Keys

After AC power has been activated and the
ON LINE -
press is operating normally, ON LINE is the normal op-
erating mode. The press can produce ultrasound signals
in this mode.
The word, Online appears in a white outlined box in the
upper right of the display.
After AC power has been activated and the press
TEST -
is operating normally, in the ON LINE mode, the TEST
key can be pushed.
This activates a momentary ultrasound pulse allowing the
operator to test system function. The display will show the
real time settings for Amplitude, Power, Operating Fre-
quency, and Distance (does not appear if distance is not
supported). This information is useful in troubleshooting.
While pushing the TEST key, look at the System Power
Output Level bar graph (See Figure 4-3.) There should be
at least one segment lit.
IMPORTANT
- If more than three segments are lit, with
no load applied to the ultrasonic stack, make sure the stack
is properly assembled and not damaged. During normal
operation, the peak level LED segment remains lit (ap-
proximately 1 second) until the next cycle begins.
After AC power has been activated and the
OFFLINE -
press is operating normally, the OFFLINE key may be
pressed to put the press into the offline mode. In this mode
the press can not generate an ultrasound signal.
However the press can still run a cycle while OFFLINE.
This can be useful to check the rest of the mechanical
weld setup including the speed, air pressure and trigger
point settings.
The word, Offline appears in a white outlined box in the
display's upper right corner.
Page 36
AUTO 01
PROCESS
STATISTICS
Figure 4-2
AUTO 01
SETUP #01
PART COUNT:
WELD TIME :
ENERGY:
PEAK POWER :
DISTANCE
PROCESS
STATISTICS
Figure 4-3
Operating Mode Indicator
Online condition shown
SETUP #01
PART COUNT:
WELD TIME :
ENERGY:
PEAK POWER :
DISTANCE
Display Detail, Operating Mode Indicator
CAUTION
If a transducer is not connected
to the ultrasound output con-
nector, the system should be
set to the OFFLINE mode. Do not ac-
tivate the ultrasound output without a
transducer connected. Make sure that
the stack is properly assembled before
it is connected to the system. The horn
should never come in direct contact with
a metal fixture or anvil with ultrasound
activated.
System Power Output Level
Bar Graph
ONLINE
0
0.000s
0J
0 W
0in
Display Detail, Power Output Level
Dukane Manual Part No. 403-594-02
ONLINE
0
0.000s
0J
0 W
0in