7-4-2 Sample Counting and ACAL

Sample Counting
1) Place samples onto the weighing pan (or into a tared container) and input the quantity
SMPL
with numeric keys, then press key
.
Symbol ― ‖ pointing at ―ACAI‖
The unit weight is calculated, with
.
Note:
●The larger the sample size, the more accurate unit weight.
●Symbol ―
‖ points at ―SMPL‖ when calculated unit weight is lower than 4/5 of scale
division or the quantity of sample is less than 10 pieces.
2) Remove the samples and put the load on, the scale begins to count.
M-/HI
3) Press key
to exit and return to the weighing mode.
ACAI
Automatic Counting Accuracy Improvement (ACAI) results in a more accurate count by
increasing the reference weight without the need to count additional parts. A higher reference
weight is important when there is a risk of inconsistent piece weights or if the reference weight
is close to the minimum. ACAI uses an initial averaging unit weight to count additional pieces
that are placed on the scale. After a few seconds, the scale gives a beep as the new higher
reference weight is used to recalculate the averaging unit weight. The process can be
repeated as long as the additional weight is less than the previous reference weight. Once
this limit is exceeded, ACAI is turned off.
Manual ACAI closing: ACAI acts automatically after sampling when ACAI indication appears.
SMPL
Long press
key to turn off ACAI when ACAI indication disappears. ACAI re-acts when
sampling again.

7-5 Accumulation, Accumulation Display and Accumulation clear

Accumulation
UWS/ITEM
1) Enter the indicated unit weight, press key
and put first piece of load on the
weighing pan (or into a tared container). (Refer to 7-4-1 and 7-4-2)
M+/SAVE
2) Press key
, the first accumulation event is displayed momentarily before