Jadever JCAII User Manual
Jadever JCAII User Manual

Jadever JCAII User Manual

Jadever jcaii counting scale user guide
Hide thumbs Also See for JCAII:

Advertisement

1. Introduction ......................................................................................................... 1
2. Precautions .......................................................................................................... 1
3. Before Using the Product ................................................................................... 1
3-1 Unpacking and Checking ......................................................................................................... 1
3-2 Installing Components ............................................................................................................. 1
3-3 Leveling the Scale .................................................................................................................... 1
4. Product Introduction ........................................................................................... 2
4-1 Display ....................................................................................................................................... 2
4-2 Keypad ...................................................................................................................................... 3
5. Analog Section .................................................................................................... 4
6. Setting mode ........................................................................................................ 4
7. Dual Channel ....................................................................................................... 5
7-1 Diagram of sub channel connector ........................................................................................ 5
7-2 Installation Process .................................................................................................................. 5
7-3 Setup ......................................................................................................................................... 6
7-4 Maximum Capacity & Division Setting ................................................................................... 6
7-5 Calibration ................................................................................................................................. 7
7-6 Set AD gain of remote platform ............................................................................................... 8
7-7 Switch between Main scale and Remote platform ................................................................. 8
8. Operation ............................................................................................................. 8
8-1 Zero-point .................................................................................................................................. 8
8-2-1Tare ................................................................................................................................... 8
8-2-2Preset Tare ........................................................................................................................ 9
8-2-3 Auto-tare .......................................................................................................................... 9
8-3 Counting method .................................................................................................................... 10
8-3-1Key in a known unit value ............................................................................................... 10
8-3-2 Sample counting ............................................................................................................ 10
8-3-3 ACAI ................................................................................................................................ 11
8-4 Accumulation ........................................................................................................................... 11
8-4-1Choose Accumulation Mode ............................................................................................ 11
8-4-2Set the Max Account of accumulation .............................................................................. 11
8-4-3Manual Accumulation ...................................................................................................... 12
8-4-4Accumulation display ...................................................................................................... 12
8-4-5Print while display of accumulation ................................................................................. 13
8-4-6Delete accumulation ........................................................................................................ 13
CONTENTS
V03
JCAII

Advertisement

Table of Contents
loading

Summary of Contents for Jadever JCAII

  • Page 1: Table Of Contents

    8-3-3 ACAI ..........................11 8-4 Accumulation ........................... 11 8-4-1Choose Accumulation Mode .................... 11 8-4-2Set the Max Account of accumulation ................11 8-4-3Manual Accumulation ...................... 12 8-4-4Accumulation display ...................... 12 8-4-5Print while display of accumulation ................. 13 8-4-6Delete accumulation ......................13 JCAII...
  • Page 2 8-9-2Saving ID method 2 ......................17 8-9-3Call up ID ........................17 8-10 Label ............................18 8-11Time Setting ........................... 18 8-12 Error message ........................19 8-13 Problem & Solution ......................19 9. Option ......................... 20 10. Relay Module Diagram ..................25 JCAII...
  • Page 3: Introduction

    1. Introduction Thank you for deciding to purchase a JCAII counting scale. This goods has the excellent performance and splendid properties under severe quality management .It is recommended to read this manual in full before using it for good function application.
  • Page 4: Product Introduction

    10)Low Battery Indicator: When “ ” appears, the battery power requires recharging. 11)CHANGE Charge Lamp Red--- battery is charging Green---battery is fully charged Symbol “ ” points at ACAI “ACAI” when Automatic counting accuracy improvement is functioning. JCAII 2...
  • Page 5: Keypad

    ·Displays gross and net weight by turns ·Inputs unit weight ·Enters the sampling mode ·Switches between main scale and remote platform ·Adds the indicated weight or piece count value into Accumulation memory. ·Enters label editing mode ·Steps to next parameter JCAII 3...
  • Page 6: Analog Section

    3 seconds to enter basic parameter setting mode. 2. Press to switch between parameters from P-00 to P-07 3. Press key to step through all the available setting options. 4. Press key to save the setting and return to weighing mode. JCAII 4...
  • Page 7: Dual Channel

    Options: n81 / o81 / e81 / n71 / o71 / e71 7. Dual Channel 7-1 Diagram of sub channel connector 7-2 Installation Process 1. Turn on the main scale 2. Connect the remote platform to JCAII main scale JCAII 5...
  • Page 8: Setup

    3) Press key advance to division setting. Use numeric keys to input the new division. 4) Press key to advance to Maximum Capacity & Division Setting of the remote platform. 5) Repeat step 2-3 to complete the settings. JCAII 6...
  • Page 9: Calibration

     You can only do the calibration for the remote platform after you have set the max. capacity and division of the remote platform. Here take JCAII-6K as an example. 1. Press key and hold while turning on the scale. Do not release till is displayed in the Unit Weight window.
  • Page 10: Set Ad Gain Of Remote Platform

    8. Operation 8-1 Zero-point Press if you do not see “ ” but symbol “ ” appears 8-2 Tare & Preset Tare 8-2-1 Tare 1. Under the weighing mode, place a container weighing (eg. 0.100kg) on the pan. JCAII 8...
  • Page 11: 8-2-2Preset Tare

    2. Use numeric key to input the high limit value. Eg. 0.1kg. 3. Press to save and return. Set the low limit of the tare value 1. Press under normal weighing mode. appears in the Total Count window. . (If not, press JCAII 9...
  • Page 12: Counting Method

    . The unit weight is calculated 3. Remove the samples and put on the articles, the scale begins to count Note: Symbol appears pointing at “ ” in the Unit Weight window when sample quantity is less than 10 pieces. JCAII 10...
  • Page 13: Acai

    The max accumulation number is 50. You can change the max accumulation number as following: For example, if you want to change the accumulation number to 9 1.Press and the Unit Weight display is blinking. 2. Press to save and return. And now you can accumulate up to 9 times only. JCAII 11...
  • Page 14: 8-4-3Manual Accumulation

    4.Skip 2-3 steps, press any numeric key to see a certain accumulation. For example, if you want to see the 12 accumulation, press key 5.Press to return to normal weighing mode. JCAII 12...
  • Page 15: 8-4-5Print While Display Of Accumulation

    1. Press key with no load on the pan. 2. Key in the Form Number with numeric key. For example, if you want to choose the 9 form, press 3. Press key to complete and return to weighing mode. JCAII 13...
  • Page 16: Set Print Mode

    The max serial number is 9999, but you can change the max serial number as shown below. For example: if you want to change the max serial number to 9, do as the following. 1.Press and the Unit Weight display is blinking. JCAII 14...
  • Page 17: 8-6-3Change The Current Serial Number

    2.Use numeric key to input the low limit of quantity you want. 3.Press to save and return. 8-7-3 Enable / Disable the quantity limit function 1.Under normal weighing mode, press . The display in the Total Count window is blinking. (If not press JCAII 15...
  • Page 18: Weight Checking

    (If not press 2. If you want to enable the function, press If you want to disable the function, press Note: When the HI & LO checking function is enabled, there will be an arrow pointing between JCAII 16...
  • Page 19: Unit Weight Id

    8-9-3Call up ID Note: If the Unit Weight display is not showing 0, please press first 1. under normal weighing mode, press 2. Use numeric key to input a certain ID. (eg. to call up ID 13) JCAII 17...
  • Page 20: Label

    8-11Time Setting 1. Press under normal weighing mode. 2. Press to enter adjusting mode. 3. Press to move leftwards and to move rightwards. Use numeric key to input the adjustment. 4. Press to save and return. JCAII 18...
  • Page 21: Error Message

     Check the baud rate (P-06) and the data (P-07) is compatible to printer. If not, please change the setting accordingly.  Under the normal weighing mode, press to print. If the printer is able to print, it means that this printer can replace the SH-24 printer. JCAII 19...
  • Page 22: Option

    = Print when weight is ok(with check function) = Print continuously =No action 3. Get receiving program ready on your computer. Commonly used 9 female ~9male RS232 connecting cable. Note: The hollow dots represent male connectors and the black dots represent female connector. JCAII 20...
  • Page 23 Can print out bar code → + 2009-05-27 14:46:38 G.W.: 1.000kg U.W.: 0.5g Total:400PCS Zebra EZ(godex) Can print out accumulation data + → SH-24 + → Only the weighing data can be shown on the LED display LED Display JCAII 21...
  • Page 24 Light tower can indicate three + different situation → LED Light Tower JCAII 22...
  • Page 25 Two optional devices being used Option Application ZEBRA/ → GODEX/ LED Display LED Light Tower/ JCAII 23...
  • Page 26 ZEBRA/ GODEX/ JCAII 24...
  • Page 27: Relay Module Diagram

    Three optional devices being used Option Application LED Display → ZEBRA/ GODEX/ LED Light Tower 10. Relay Module Diagram RELAY OUTPUT: Alarm C O M N . C . N . O . JCAII 25...
  • Page 28 C O M N . C . N . O . C O M N . C . N . O . C O M N . C . N . O . RELAY CONTACT SPEC 1A/24VDC,0.5A/125VAC,0.25A/250VDC JCAII 26...

Table of Contents