Jadever JWE User Manual

Jadever JWE User Manual

High precision check weigher and bench scale
Hide thumbs Also See for JWE:

Advertisement

.........................................................................................
..........................................................................................
3-1 Unpacking and Checking.............................................................................
3-2 Installing Components ................................................................................
3-3 Leveling the Scale......................................................................................
4-1 Specifications & General Features .....................................................................
4-2-1 Display .................................................................................................
4-2-2 Keyboard..............................................................................................
4-3 Power Supply...........................................................................................
5-1 Weighing..................................................................................................
5-2 Tare .......................................................................................................
5-3 Weight Checking.......................................................................................
5-4 Simple Counting.......................................................................................
5-5 Percentage Weighing .................................................................................
6-1 Single Point Calibration ..............................................................................
6-2 Linear Calibration......................................................................................
8-1 RS-232 Connector....................................................................................
8-2 Single Option...........................................................................................
8-3 RS-232 Output Format...............................................................................

Table of Contents

.......................................................
JWE
.................................
1
1
1
1
1
2
3
4
4
4
5
5
6
6
6
7
7
8
10
10
10
13
0

Advertisement

Table of Contents
loading

Summary of Contents for Jadever JWE

  • Page 1: Table Of Contents

    Table of Contents 1. Introduction ………………………………….…………………………………………. 2. Precautions …………………………………….……………………………………….. 3. Before Using the Product 3-1 Unpacking and Checking………………………………………………………………….. 3-2 Installing Components ………………………………………..…………………………… 3-3 Leveling the Scale………………………………………………..………………………… 4. Product Introduction 4-1 Specifications & General Features …………………………………......4-2 Front Panel 4-2-1 Display …….……………………………………………………………………………… 4-2-2 Keyboard………………………………………………………………………………….
  • Page 2: Introduction

    1. Introduction Thank you for deciding to purchase a JWE Weighing scale from Jadever. This goods has the excellent performance and splendid properties under severe quality management .It is recommended to read this manual in full before using it for good function application.
  • Page 3: Product Introduction

    4) Power socket 5) On/Off Switch 6) HI-LO-OK Signal Output and Bilateral RS-232 Standard Interface 7) Print Button 8) Two-stage Switch 9) Bubble Level Indicator 4-1 Specifications & General Features Specifications Model JWE-3K JWE-6K JWE-15K JWE-30K Capacity 3000g 6000g 15kg 30kg Division(g) 0.1g...
  • Page 4: Front Panel

    General Features ‧3kg/0,1g~30kg/1g ‧1/30,000 display resolution ‧Water-resistant durable keypad ‧ Auto power off / Auto backlight ‧HI/LO/OK setting can be stored ‧HI/LO/OK alarm function ‧Soft-ware filtering ‧Stainless steel weighing pan is for long-term operation ‧Operated by power supply or rechargeable battery ‧Internal battery charger ‧Clear LCD display with backlight ‧Overweight and delivery protection...
  • Page 5: Keyboard

    4-2-2 Keyboard M+/MR key Memory /Memory recall MC/SET key Enables weight checking function /clear previous accumulation data MODE Cycles through kg, g, lb, lb-oz,斤, 台斤, 港斤,pcs and %( Enable 斤、台 斤 and 港斤 under the setting mode if needed .) TARE key Tares the weight of the pan / shiftkey, moves to the left.
  • Page 6: Tare

    5-2 Tare When weighing a sample that must be held in a container, tare stores the container weight into memory. Tare 1) Under the weighing mode, place the container on the weighing pan, wait till stable indicator TARE appears, and press the key .
  • Page 7: Simple Counting

    5-4 Simple Counting MODE 1) Under the weighing mode, press key to select the unit “PCS” MC/SET 2) Press key to choose the sampling amount (Options are 25, 50 and 100), then put the simples on the weighing pan. 3) Wait till the appearance of CAL 4) Two seconds later, the sampling action ends up with a beep.
  • Page 8: Calibration

    3)Press key to select calibration weight value. Options are1/3 of full load, 2/3 of full load and full load. E.g., options for JWE-3K are 1, 2 and 3(kg). 4)Put the corresponding weights on the weighing pan, then the calibration procedure starts.
  • Page 9: Setting Mode& Description Of Parameter Values

    1/3 of full load on the weighing pan and press TARE down key E.g., for JWE-3K ,1/3 of full load is 1kg. 4) Wait till appears, and then put weights of 2/3 of full load on pan and press down TARE E.g., for JWE-3K, 2/3 of full load is 2kg.
  • Page 10: Serial Interface

    Set the filtering level in which the stable indication turns on .The higher the setting, the slower stabilization time. Options are Fil 1,Fil 2,Fil 4 and Fil 8. Set the period of inactivity before the scale automatically turns off. Options are Aut.NO=non power-off,Aut.5, Aut.10, Aut.30 and Aut.60(minutes).
  • Page 11: Rs-232 Connector

    8-1 RS-232 Connector 8-2 Single Option 1) RS232+RTC+Relay+ TDP / SH-24(TP)/ ZEBRA / GODEX(EZ)printer 2) RS232+RTC+Relay+ LED Light Tower (Applicable to the quality control of the factory product quantity or weight and that of the total production line.) 3) RS232+RTC+Relay+Computer 8-3 RS-232 Output Format Baud Rate :...
  • Page 12 Example: T.W.: + 1.000 kg N.W.: + 1.000 kg G.W.: + 2.000 kg 2、g G/N/ : CR LF Weight Example: T.W. : N.W. : + 1000.0 G.W. : + 1000.0 3、lb G/N/ : CR LF Weight Example: T.W. : + 2.2050 lb N.W.: + 2.2050 lb G.W.:...
  • Page 13 Example: T.W. : + 1-10.5G-tl.H N.W. : + 1-10.5G-tl.H G.W. : + 3- 4.9G-tl.H 6、斤 G/N/ : CR LF Weight Example: T.W. : + 2.0000 C-Jing N.W. : + 1.9998 C-Jing G.W. : + 3.9998 C-Jing 7、lb/oz G/N/ : CR LF Weight Example:...
  • Page 14: Troubleshooting And Error Message

    9. % Example: + 24% G = GROSS N = NET 9. Troubleshooting and Error Message Error message Problems Solutions 1. Check whether there are other alien Initial zero point exceeds articles on the scale pan, remove those + /-30% (take 10% as articles.

Table of Contents