1. Introduction ........................................................................................................... 1
2. Precautions ........................................................................................................... 1
3. Before Using the Product..................................................................................... 1
3-1 Unpacking and Checking......................................................................................................... 1
3-2 Installing Components ............................................................................................................. 1
3-3 Leveling the Scale .................................................................................................................... 1
4. Product Introduction ............................................................................................ 2
4-1 Display....................................................................................................................................... 2
4-2 Keypad ...................................................................................................................................... 3
5. Analog Section...................................................................................................... 4
6. Setting mode ......................................................................................................... 4
7. Dual Channel ......................................................................................................... 5
7-1 Diagram of sub channel connector......................................................................................... 5
7-2 Installation Process.................................................................................................................. 5
7-3 Setup ......................................................................................................................................... 6
7-4 Maximum Capacity & Division Setting & Unit ........................................................................ 6
7-5 Calibration................................................................................................................................. 7
7-6 Set AD gain of remote platform ............................................................................................... 8
7-7 Switch between Main scale and Remote platform................................................................. 8
8. Operation............................................................................................................... 8
8-1 Zero-point.................................................................................................................................. 8
8-2-1 Tare .................................................................................................................................. 9
8-2-2Preset Tare........................................................................................................................ 9
8-2-3 Auto-tare .......................................................................................................................... 9
8-3 Counting method.................................................................................................................... 10
8-3-1Key in a known unit value ............................................................................................... 10
8-3-2 Sample counting ............................................................................................................ 10
8-3-3 ACAI................................................................................................................................11
8-3-4 Simple Recipe Function .................................................................................11
8-4 Accumulation.......................................................................................................................... 12
8-4-1 Choose Accumulation Mode .......................................................................................... 12
8-4-2 Set the Max Account of accumulation ............................................................................ 12
8-4-3 Manual Accumulation ..................................................................................................... 12
8-4-4 Accumulation display...................................................................................................... 13
8-4-5 Print while display of accumulation ................................................................................ 13
8-4-6 Delete accumulation....................................................................................................... 13
8-5 Print ......................................................................................................................................... 14
CONTENTS
V03
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
JCAII

Advertisement

Table of Contents
loading

Summary of Contents for Jadever JCAII

  • Page 1: Table Of Contents

    8-4-2 Set the Max Account of accumulation ................12   8-4-3 Manual Accumulation ..................... 12   8-4-4 Accumulation display...................... 13   8-4-5 Print while display of accumulation ................13   8-4-6 Delete accumulation....................... 13   8-5 Print ............................14   JCAII...
  • Page 2 8-9-3Call up ID ........................20   8-10Label ............................20   8-11Time Setting ........................... 21   8-12 Error message ........................21   8-13 Problem & Solution ......................22   9. Option ........................23   10. Relay Module Diagram ..................28   JCAII...
  • Page 3: Introduction

    1. Introduction Thank you for deciding to purchase a JCAII counting scale. This goods has the excellent performance and splendid properties under severe quality management .It is recommended to read this manual in full before using it for good function application.
  • Page 4: Product Introduction

    10)Low Battery Indicator: When “ ” appears, the battery power requires recharging. 11)CHANGE Charge Lamp Red--- battery is charging Green---battery is fully charged Symbol “ ” points at “ACAI” when Automatic counting accuracy improvement is ACAI functioning. JCAII 2...
  • Page 5: Keypad

    ·Enters the sampling mode and change its scale choice(scale 1 or 2) ·Switches between main scale and remote platform ·Adds the indicated weight or piece count value into Accumulation memory. ·Enters label editing mode ·Steps to next parameter JCAII 3...
  • Page 6: Analog Section

    1. Under the weighing mode, long press key for 3 seconds to enter basic parameter setting mode. 2. Press to switch between parameters from P-00 to P-07 3. Press key to step through all the available setting options. JCAII 4...
  • Page 7: Dual Channel

    Options: n81 / o81 / e81 / n71 / o71 / e71 7. Dual Channel 7-1 Diagram of sub channel connector 7-2 Installation Process 1. Turn on the main scale 2. Connect the remote platform to JCAII main scale JCAII 5...
  • Page 8: Setup

    3) Press key advance to division setting. Use numeric keys to input the new division. 4) Press key to advance to Maximum Capacity & Division Setting of the remote platform. 5) Repeat step 2-3 to complete the settings. JCAII 6...
  • Page 9: Calibration

    You can only do the calibration for the remote platform after you have set the max. capacity and division of the remote platform. Here take JCAII-6K as an example. 1. Press key and hold while turning on the scale. Do not release till is displayed in the Unit Weight window.
  • Page 10: Set Ad Gain Of Remote Platform

    Weight Window. 5. When flashing disappear, means that the scale have returned back to main scale mode. 8. Operation 8-1 Zero-point Press if you do not see “ symbol “ ” appears ” but JCAII 8...
  • Page 11: Tare & Preset Tare

    Total Count window. (If not, press 2. Use numeric key to input the high limit value. Eg. 0.1kg. 3. Press to save and return. Set the low limit of the tare value JCAII 9...
  • Page 12: Counting Method

    8-3-2 Sample counting Note: Do tare or zero-point before doing the following steps 1. Put samples onto the weighing pan and input the quantity with the numeric key. (eg. 0.300kg, 20pcs) 2. Press key . The unit weight is calculated JCAII 10...
  • Page 13: Acai

    Repeat the same operation until get all material needed for a recipe. 4. Press MR to check all accumulation items. 5. Clear the weighing pan and press TARE to continue a second recipe weighing. JCAII 11...
  • Page 14: Accumulation

    Press twice to delete all accumulation, 8-4-3 Manual Accumulation 1. Put the article on the pan. Press key . The symbol “ ” is blinking in the Unit JCAII 12...
  • Page 15: Accumulation Display

    Weight on the scale will print out every set and total No weight on the scale will just print out the total 8-4-6 Delete accumulation Delete a certain accumulation 1. Enter a certain accumulation display, press to delete. JCAII 13...
  • Page 16: Print

    2. Key in the Form Number with numeric key. For example, if you want to choose the 9 form, press 3. Press key to complete and return to weighing mode. Samples of BP/ EZ Print Forms (Preset 10 forms, at most 100 forms) JCAII 14...
  • Page 17 100mm as the bar code is longer.) Samples of SH-24 Print Forms Prt08-15 print forms Prt08-15 print forms with unit weight with tare weight When appear under display of accumulation, press .the printout will be as following. JCAII 15...
  • Page 18: Set Print Mode

    = BP printer output (Automatic-sticking), paper size: 5cm*3cm = ZEBRA printer output (Automatic-sticking), paper size: 5cm*3cm = SH-24 printer output (dot-matrix) = EZ printer output (Automatic-sticking), paper size: 5cm*3cm = Normal compatible printer = LED display = Adhesive sticker label JCAII 16...
  • Page 19: Serial Number

    For example: if you want to change the serial number to 9, do as the following. 1. Press and the Unit Weight display is blinking. 2. Press to save and return. Note: the serial number is starting from 9. JCAII 17...
  • Page 20: 8-7Quantity Check

    Note: When the HI & LO checking function is enabled, there will be an arrow pointing between PERSET TARE and NET. 8-8 Weight check 8-8-1Set the high limit of weight 1. Press under normal weighing mode. The display of the weight is blinking in the Weight JCAII 18...
  • Page 21: 8-8-2Set The Low Limit Of Weight

    PERSET TARE and NET. 8-9 Unit weight ID Note: possible save up to 50 ID 8-9-1Saving ID method 1 For example, save 1.23g to ID 12 1. Press under normal weighing mode and the Unit Weight is blinking. JCAII 19...
  • Page 22: 8-9-2Saving Id Method 2

    2. Use numeric key to input a certain ID. (e.g. to call up ID 13) 3. Press to confirm and the scale is ready for counting. 8-10Label Set your own label Note: The label can save up to 32 characters JCAII 20...
  • Page 23: 8-11Time Setting

    Return to the Manufacturer EEPROM Unable to read the 3 points Do the 3 points calibration calibration range Zero Point is too high Make sure the pan is empty when turn on the scale or perform the 3 points calibration. JCAII 21...
  • Page 24: Problem & Solution

    No sound in HI & LO checking function Make sure the parameter P-03 is set correctly. Reset the time every time when the scale is turned on Connect an optional RTC How to check whether the printer is compatible to the scale JCAII 22...
  • Page 25: Option

    1. Connect the scale and computer by using the RS232 cable as the following picture. 2. Please set the print mode = Manual = Print after appears = Print when quantity is ok(with check function) = Print when weight is ok(with check function) JCAII 23...
  • Page 26 US=UNSTABLE) ( header2: NT=NET GS=GROSS) examples for Case1: examples for Case2: ST /NT□+□12.350□kg ST /NT□+□10.000□kg,1.0000□□g, □10000□PCS US/GS□+□30.000□lb US/GS□+□30.000□l b,0.0010□ l b, □30000□PCS Only one optional device being used Option application Remark Can print out bar code → + JCAII 24...
  • Page 27 Total:400PCS Zebra EZ(godex) Can print out accumulation data + → SH-24 + → Only the weighing data can be shown on the LED display LED Display Light tower can indicate three different situation + → LED Light Tower JCAII 25...
  • Page 28 Two optional devices being used Option Application ZEBRA/ → LED Display GODEX/ LED Light Tower/ JCAII 26...
  • Page 29 ZEBRA/ GODEX/ Three optional devices being used JCAII 27...
  • Page 30: Relay Module Diagram

    Option Application LED Display → ZEBRA/ GODEX/ LED Light Tower 10. Relay Module Diagram RELAY OUTPUT: Alarm N.C. N.O. JCAII 28...
  • Page 31 N.C. N.O. N.C. N.O. N.C. N.O. RELAY CONTACT SPEC 1A/24VDC,0.5A/125VAC,0.25A/250VDC JCAII 29...