8.5.5
The object velocity min max amount comprises the subindex 01 = velocity min
amount and subindex 02 = velocity max amount.
The velocity min amount variable corresponds with the parameter value
Frequency
positive values) and is converted internally to a frequency, taking the object pole
number into account. The value is not stored and is set back to zero after the reset.
The value for the object velocity max amount is written internally onto the parameter
value
After the reset, the object value velocity max amount is converted into the unit RPM
from the parameter
If the reference value with the object target velocity is specified smaller than the
object value velocity min amount or larger than velocity max amount, target velocity is
internally limited to the values in question.

0x6046/n Velocity min max amount

Note:
06/05
06/05
0x6046/n Velocity min max amount
Index
Subindex
0x6046
0
Number of entries (unsigned 8)
1
Velocity min amount (RPM)
2
Velocity max amount (RPM)
418 in the first data set. The specification is done in the unit RPM (only
Maximum Frequency
Maximum Frequency
Parameter
No.
Velocity max amount
Velocity min amount
The object velocity min amount is always set to the object value = 0 after
the reset of the frequency inverter.
Velocity min max amount
Meaning
419 in data set 1 in the form of a converted frequency.
419.
Object
Output
Velocity min amount
Velocity max amount
Value
2
(unsigned 32)
(unsigned 32)
Minimum
Setting
Min.
Max.
0
32767
Input
23
23