6.3 Configuring Outputs

To configure an output, follow the procedure below.
1. On the menu bar click on Config->Ports and Pins.
2. Select the Output Signals tab.
3.
Scroll down to the desired output (There are 20 outputs that can be used).
Note: The note below the output signal window is referencing parallel port systems. Ignore this.
4. Enable the output by setting the Enabled box to a green check.
5. Set the Port Number to 11 and the Pin Number to the corresponding Y number (Y3 would be pin number
3).
6. Set the Active Low column to a green check for a normally closed signal or red x for normally open.

6.4 Using Outputs

Outputs 5-10 can be controlled with M-Codes. One M-Code turns an output on, and the other M-Code turns the
output off. Use the table below for a reference.