9.
Repeat starting at step 3 for each additional axis.
10. Restart Mach3 to save the calibration settings.

2.3.2 Calibration Wizard

Complete the following procedure to use the calibration wizard:
1. Run "M9990" from the MDI line.
2. Select the axis to calibrate.
3. Enter in the distance and federate the axis should move.
4. Measure how far the axis moved.
5. Enter in the distance the axis moved.
6. Allow it to update the Steps Per Unit for that axis if the measurement was correct.
7. Repeat this procedure until the axis is within the required accuracy.
If you want to adjust your velocity, select Config on the top menu bar, then Motor Tuning. You should see the
Motor Tuning and Setup window as shown below.
In the column titled Axis Selection, press the button corresponding to the axis you want to set up. The selected
axis's parameters will be loaded. Now you can adjust your velocity setting as shown below.
FIGURE 13 MOTOR TUNING AND SETUP