Assembling and connecting the safety ground wire
Prerequisite
WARNING:
For equipment using –(48–60) V DC power supply units (PSUs), a qualified electrician must perform all connections
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring
must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
Steps
1
Strip the insulation from the end of the green or yellow wire, exposing approximately 4.5 mm (0.175 inch) of copper wire.
2
Using a hand-crimping tool (Tyco Electronics, 58433-3 or equivalent), crimp the ring-tongue terminal (Jeeson Terminals Inc., R5-4SA
or equivalent) to the green or yellow wire (safety ground wire).
3
Connect the safety ground wire to the grounding post on the back of the system by using a #6-32 nut equipped with a locking
washer.
Figure 68. Assembling and connecting the safety ground wire
1
#6-32 nut
3
grounding post
Figure 69. Removing the safety ground wire
1
#6-32 nut
3
grounding post
2
spring washer
4
safety ground wire
2
spring washer
4
safety ground wire
Installing and removing system components