Error Messages (Cutting Machine)
Cannot find SSID. Press [OK] button.
PC connection error. Press [OK] button.
WLAN connection failed. Press [OK] button.
Network error. Turn the machine off, then on
again.

DesignNCut Manager Error

Error Code
(Cutting
Error Messages (DesignNCut Manager)
Machine)
DesignNCut is unavailable while it is
connecting to another DesignNCut
E002
Manager. To cancel the connection, restart
DesignNCut.
Cannot connect to machine.
E003
Select an appropriate connection mode for
the settings on DesignNCut.
The version of machine and DesignNCut
E004
Manager doesn't match.
Confirm the versions and update.
E204
No pattern in the effective area.
E207
Attach an appropriate holder.
Data cannot be read on DesignNCut.
E217
The file size is too big.
Cannot continue as the data has too many
E218
objects.
As shown below, the cause and solution differ depending on when this
message appeared.
- Appeared after running [2.Setup Wizard] to search for an SSID
Possible Cause: Failed to detect an SSID
Solution: Check the information described for 1. of (Err-02).
- Appeared when [Saved SSID] is selected in the window listing the
detected SSIDs
Possible Cause: There is no SSID previously connected to the wireless
network.
Solution: Select an SSID that appeared in the window, and then set up a
wireless connection.
Failed to connect to the computer when setting up the wireless
connection using the dedicated application "WLAN Assistant Wizard"
(WAW).
Check the following, and then try performing the operation again.
- Start up WAW on the computer, and then follow the on-screen
instructions to complete the procedure.
- Check that a wireless network connection has been established between
the computer running WAW and the access point/router.
Failed to set up the wireless connection using the dedicated application
"WLAN Assistant Wizard" (WAW <USB>).
Check the following, and then try performing the operation again.
- Start up WAW <USB> on the computer, and then follow the on-screen
instructions to complete the procedure.
- Check that the machine and computer are connected with a USB cable.
- Check the possible causes and solutions for (Err-01) to (Err-05) and for
(Err-20).
An internal malfunction occurred.
Contact the retailer where you purchased this machine or the nearest
authorized service center.
Turn off the machine, turn it on again, and then make the
connection again.
Select the same connection method as that selected on the
machine.
For details on selecting the same connection method as
that on the machine, see "CONNECTING THE MACHINE
AND COMPUTER" on page 12.
DesignNCut Manager and the machine's software must be
updated. (P. 63)
There is no pattern(s) to be cut out or drawn within the
cutting area.
Edit the pattern in ScanNCutCanvas to position it within the
cutting/drawing area.
A holder incompatible with the mode has been installed.
Install a compatible holder. (P. 32)
The data file is too large. Simplify the pattern in
ScanNCutCanvas to reduce the data to 1 MB or less.
There are too many patterns. Reduce the number of
patterns in ScanNCutCanvas to 300 or less.