2.
For the installer
2.3.13 Installing the thermocontrol sensor
– Route the thermocontrol sensor (green cable) at the front of the right side panel down and feed through – Fig. 47.
Fig. 48. But first bend the cut-out (feed-through) at the bottom of the side panel out of the way.
– Insert the sensor over the ash door in the front and into the protective tube; hook the spring in place – Fig. 49.
Fig. 50.
CAUTION
– Secure the thermocontrol sensor cable to the side panel with a cable tie – Fig. 50.
Fig. 47
Inserting the thermocontrol sensor
at the top
Fig. 49
Fixing the thermocontrol sensor with
spring
2.3.14 Installing the thermocontrol sensor cover
– Attach the thermocontrol sensor with 4 self-tapping screws – Fig. 51.
2 each of
Fig. 51
Attaching the cover in front of the thermocontrol sensor with 4 screws
Pull the protruding thermocontrol sensor cable back into the side panel or control pan-
el. The cable must not sag. as otherwise it could get caught in the ash door.
Fig. 48
Threading through thermocontrol
sensor
Fig. 50
Pulling back the cable and securing
it with cable ties
25
Cut-out feed-
through
Cable tie
2 each of