3.
Care, cleaning and maintenance

3.3.5 Draught limiter (swinging draught flap)

Recommended cleaning implement: Spatula
If a draught limiter is fitted (by customer in flue or exhaust pipe), check this for ease of movement and if necessary
clean or have adjusted by a specialist.

3.3.6 Filling, lighting and ash door

Recommended cleaning implement: Spatula
– Open the doors. Door seals must leave a clean imprint. Remove any crusting and deposits that could impair the door
seals and ease of movement.
If the door seals do not leave a clean imprint or are not sealed, adjust the doors and/or replace the seals.
– If the doors do not move freely, lubricate the bearings of the door hinges with heat-resistant paste (e.g. graphite
paste).

3.3.7 Thermocontrol sensor

Recommended cleaning implement: Brush, soft cloth
– Clean fly ash off the thermocontrol sensor with a brush or soft cloth – Fig. 39.
Fig. 39
Cleaning the thermocontrol sensor
Thermocontrol sensor