Ip-Acm Installation; Plastic Enclosure - Tyco iSTAR Ultra Installation And Configuration Manual

Door controller
Table of Contents

Advertisement

Installation

IP-ACM Installation

2–8
iSTAR Ultra Installation and Configuration Guide
The IP-ACM is mounted separately from the Ultra GCM in a plastic or metal enclosure. The
following sections detail the enclosures and their installation with the IP-ACM board.

Plastic Enclosure

Table 2-4: IP-ACM and Reader Plastic Enclosure Dimensions
Item
Weight
Height
Width
Depth
To Install the IP-ACM and Plastic Enclosure:
1. Lift the enclosure cover off of the plastic IP-ACM enclosure.
2. Secure the IP-ACM enclosure to the selected wall or support surface using holes provided
in the enclosure's molded base. Refer to Figure 3 for dimensions and hole pitch for
mounting.
It is essential to use all five securing screws when mounting the plastic
NOTE
enclosure. Ensure that the mounting hole at 13.1 across and 26.3 up is used as
this is required for the "whole unit off the wall" anti-tamper feature to be
operational.
3. Fit and connect all customer cables. Refer to
power and wiring requirements of the IP-ACM.
FIGURE 3. Plastic Enclosure for the IP-ACM
Table 7-2
Dimension
2.2lb (1kg)
12.1in (307mm)
7.2in (183mm)
2.46in (62.4mm)
for more information about the