Maximum Power

• Dry Relay: 0 to 30 Vdc , 5A max. NO, 3A max. NC
The ISTAR Ultra system power ratings are listed in
Voltage
(Vdc)
System Power Ratings:
12
Voltage
(Vdc)
System Power Ratings:
12
12
12
12
12
Lock 1 and 2 Power Ratings:
0 - 30
0 - 30
0 - 30
0 - 30
0 - 30
Voltage
Current
(Vdc)
(A)
System Power Ratings (when sourcing both GCM and ACMs):
12
3.99
12
4.99
12
7.99
Table 4-1: iSTAR Ultra GCM Rack System Ratings
Local External
Current
Circuit Breaker
(A)
Rating (A)
4.49
-
Table 4-2: iSTAR Ultra ACM Rack Ratings
Local External
Current
Circuit Breaker
(A)
Rating (A)
5
-
8
10
9.5
12
11
15
12.5
29
4.5
-
6
7.5
7.5
10
9
12
12
15
Table 4-3: iSTAR Ultra Wall Mount Ratings
Local External
Circuit Breaker
Rating (A)
System Description
-
(1) GCM with (1) RS-485 Loads & (2) ACM with no loads
-
(1) GCM with (2) RS-485 Loads & (1) ACM with no loads
10
(1) GCM with (2) RS-485 Loads & (1) ACM with
(2) Wiegand/RS485/Aux load
iSTAR Ultra Installation and Configuration Guide
Table 4-1
through
Table
System Description
(1) GCM with (2) RS-485 Loads
System Description
(1) ACM with (3) Wiegand/RS485/Aux load
(1) ACM with (5) Wiegand/RS485/Aux load
(1) ACM with (6) Wiegand/RS485/Aux load
(1) ACM with (7) Wiegand/RS485/Aux load
(1) ACM with (8) Wiegand/RS485/Aux load
(6) Locks
(8) Locks
(10) Locks
(12) Locks
(16) Locks
Power Requirements
4-3.
4–3